Quality assessment of MEG-to-MRI coregistrations
- 22 March 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (7) , 075003
Abstract
For high precision in source reconstruction of magnetoencephalography (MEG) or electroencephalography data, high accuracy of the coregistration of sources and sensors is mandatory. Usually, the source space is derived from magnetic resonance imaging (MRI). In most cases, however, no quality assessment is reported for sensor-to-MRI coregistrations. If any, typically root mean squares (RMS) of point residuals are provided. It has been shown, however, that RMS of residuals do not correlate with coregistration errors. We suggest using target registration error (TRE) as criterion for the quality of sensor-to-MRI coregistrations. TRE measures the effect of uncertainty in coregistrations at all points of interest. In total, 5544 data sets with sensor-to-head and 128 head-to-MRI coregistrations, from a single MEG laboratory, were analyzed. An adaptive Metropolis algorithm was used to estimate the optimal coregistration and to sample the coregistration parameters (rotation and translation). We found an average TRE between 1.3 and 2.3 mm at the head surface. Further, we observed a mean absolute difference in coregistration parameters between the Metropolis and iterative closest point algorithm of ( 1.9 ± 15 ) ∘ and ( 1.1 ± 9 ) m. A paired sample t -test indicated a significant improvement in goal function minimization by using the Metropolis algorithm. The sampled parameters allowed computation of TRE on the entire grid of the MRI volume. Hence, we recommend the Metropolis algorithm for head-to-MRI coregistrations.Keywords
All Related Versions
This publication has 26 references indexed in Scilit:
- Linear Least Squares Problems2014
- MEG and EEG data analysis with MNE-PythonFrontiers in Neuroscience, 2013
- Single Camera Photogrammetry System for EEG Electrode Identification and LocalizationAnnals of Biomedical Engineering, 2010
- Fiducial registration error and target registration error are uncorrelated2009
- DRAM: Efficient adaptive MCMCStatistics and Computing, 2006
- 3D statistical neuroanatomical models from 305 MRI volumes2005
- Co-registration of magnetoencephalography with magnetic resonance imaging using bite-bar-based fiducials and surface-matchingClinical Neurophysiology, 2004
- Coordinate system matching for neuromagnetic and morphological reconstruction overlayIEEE Transactions on Biomedical Engineering, 1995
- A method for registration of 3-D shapesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992
- Magnetometer Position Indicator for Multichannel MEG1989