Interaction of the Hydrophobic Tip of an Atomic Force Microscope with Oligopeptides Immobilized Using Short and Long Tethers
Authors:
Open Access
- 18 March 2016
- journal article
- research article
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 32 (12) , 2985-2995
Abstract
We report an investigation of the adhesive force generated between the hydrophobic tip of an atomic force microscope (AFM) and surfaces presenting oligopeptides immobilized using either short (~1 nm) or long (~60 nm) tethers. Specifically, we used either sulfosuccinimidyl-4-(N-maleimidomethyl)cyclohexane-1-carboxylate (SSMCC) or 10 kDa polyethyleneglycol (PEG) end-functionalized with maleimide and N-hydroxysuccinimide groups to immobilize helical oligomers of β-amino acids (β-peptides) to mixed monolayers presenting tetraethyleneglycol (EG4) and amine-terminated EG4 (EG4N) groups. When SSMCC was used to immobilize the β-peptides, we measured the adhesive interaction between the AFM tip and surface to rupture through a single event with magnitude consistent with the interaction of a single β-peptide with the AFM tip. Surprisingly, this occurred even when on average, multiple β-peptides where located within the interaction area between the AFM tip and surface. In contrast, when using the long 10 kDa PEG tether, we observed the magnitude of the adhesive interaction as well as the dynamics of the rupture events to unmask the presence of the multiple β-peptides within the interaction area. To provide insight into these observations, we formulated a simple mechanical model of the interaction of the AFM tip with the immobilized β-peptides and used the model to demonstrate that adhesion measurements performed using short tethers (but not long tethers) are dominated by the interaction of single β-peptides because (i) the mechanical properties of the short tether are highly non-linear, thus causing one β-peptide to dominate the adhesion force at the point of rupture, and (ii) the AFM cantilever is mechanically unstable following the rupture of the adhesive interaction with a single β-peptide. Overall, our study reveals that short tethers offer the basis of an approach that facilitates measurement of adhesive interactions with single molecules presented at surfaces.Keywords
Funding Information
- Division of Chemistry (CHE-1307365)
- Army Research Office (W911NF-11-1-0251, W911NF-14-1-0140)
- Division of Materials Research (DMR-0832760, DMR-1121288)
This publication has 58 references indexed in Scilit:
- Modulation of hydrophobic interactions by proximally immobilized ionsNature, 2015
- Force spectroscopy 101: how to design, perform, and analyze an AFM-based single molecule force spectroscopy experimentCurrent Opinion in Chemical Biology, 2011
- Single-Molecule Force Spectroscopy of β-Peptides That Display Well-Defined Three-Dimensional Chemical PatternsJournal of the American Chemical Society, 2011
- Single-Molecule Force Spectroscopy: A Method for Quantitative Analysis of Ligand–Receptor InteractionsNanomedicine, 2010
- Chemical Force Microscopy of Single Live CellsNano Letters, 2007
- Chemical force microscopy of chemical and biological interactionsSurface and Interface Analysis, 2006
- Detection and localization of single molecular recognition events using atomic force microscopyNature Methods, 2006
- Force measurements with the atomic force microscope: Technique, interpretation and applicationsSurface Science Reports, 2005
- Single molecule force spectroscopy in biology using the atomic force microscopeProgress in Biophysics and Molecular Biology, 2000
- Introductory Lecture Energy landscapes of biomolecular adhesion and receptor anchoring at interfaces explored with dynamic force spectroscopyFaraday Discussions, 1999