Fully automated on‐screen carotid intima‐media thickness measurement: A screening tool for subclinical atherosclerosis
- 28 March 2013
- journal article
- clinical trial
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 41 (6) , 333-339
Abstract
Purpose: Carotid intima‐media thickness (CIMT) is generally considered an appropriate direct vascular method for cardiovascular risk assessment. The objective of this study was to evaluate the feasibility and reproducibility of a newly developed automated on‐screen carotid ultrasound with respect to manual measurement with a conventional system.Methods: We assessed CIMT in 50 consecutive patients (age 62 ± 5 years, range 21–79 years, 36 men) twice, using a newly developed automated ultrasound (CardioHealth Station) and a conventional system with manual measurement (Acuson, Sequoia). For each patient, three frozen frames of the distal 10 mm of the right and left common carotid arteries were acquired on the two systems, by operators blinded to each other. The average of the mean value of three readings of each system was calculated.Results: The intraclass correlation coefficient of the interoperator variability was 0.95 and 0.94 for the automated and manual measurements, respectively. The comparative coefficient of variation of the interoperator variability was 8.2 and 8.7% for the automated and manual measurements, respectively. There was no clinically relevant difference between measurements obtained by the two systems (intraclass correlation coefficient = 0.98). The acquisition time of the automated system was significantly shorter than the conventional system (p < 0.01).Conclusions: Fully automated on‐screen measurements of CIMT are feasible, faster, and as reproducible as conventional manual measurements and may be suitable and cost‐effective for screening application in community medicine. © 2013 Wiley Periodicals, Inc. J Clin Ultrasound 41:333–339, 2013Keywords
This publication has 20 references indexed in Scilit:
- Ultrasound IMT measurement on a multi-ethnic and multi-institutional database: Our review and experience using four fully automated and one semi-automated methodsComputer Methods and Programs in Biomedicine, 2012
- Carotid Intima-Media ThicknessUltrasound Quarterly, 2009
- Ultrasound protocols to measure carotid intima–media thickness: a post-hoc analysis of the OPAL studyCurrent Medical Research and Opinion, 2008
- Validation of a new automated IMT measurement algorithmJournal of Human Hypertension, 2007
- A semiautomated ultrasound border detection program that facilitates clinical measurement of ultrasound carotid intima-media thicknessJournal of the American Society of Echocardiography, 2005
- Mannheim Intima-Media Thickness ConsensusCerebrovascular Diseases, 2004
- Carotid Intima-Media Thickness Measurements in Intervention StudiesStroke, 2003
- A multiscale dynamic programming procedure for boundary detection in ultrasonic artery imagesIEEE Transactions on Medical Imaging, 2000
- A comparison of the Two One-Sided Tests Procedure and the Power Approach for assessing the equivalence of average bioavailabilityJournal of Pharmacokinetics and Biopharmaceutics, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986