Validation of the Better Care® system to detect ineffective efforts during expiration in mechanically ventilated patients: a pilot study
- 2 February 2012
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 38 (5) , 772-780
Abstract
Ineffective respiratory efforts during expiration (IEE) are a problem during mechanical ventilation (MV). The goal of this study is to validate mathematical algorithms that automatically detect IEE in a computerized (Better Care®) system that obtains and processes data from intensive care unit (ICU) ventilators in real time. The Better Care® system, integrated with ICU health information systems, synchronizes and processes data from bedside technology. Algorithms were developed to analyze airflow waveforms during expiration to determine IEE. Data from 2,608,800 breaths from eight patients were recorded. From these breaths 1,024 were randomly selected. Five experts independently analyzed the selected breaths and classified them as IEE or not IEE. Better Care® evaluated the same 1,024 breaths and assigned a score to each one. The IEE score cutoff point was determined based on the experts’ analysis. The IEE algorithm was subsequently validated using the electrical activity of the diaphragm (EAdi) signal to analyze 9,600 breaths in eight additional patients. Optimal sensitivity and specificity were achieved by setting the cutoff point for IEE by Better Care® at 42%. A score >42% was classified as an IEE with 91.5% sensitivity, 91.7% specificity, 80.3% positive predictive value (PPV), 96.7% negative predictive value (NPV), and 79.7% Kappa index [confidence interval (CI) (95%) = (75.6%; 83.8%)]. Compared with the EAdi, the IEE algorithm had 65.2% sensitivity, 99.3% specificity, 90.8% PPV, 96.5% NPV, and 73.9% Kappa index [CI (95%) = (71.3%; 76.3%)]. In this pilot, Better Care® classified breaths as IEE in close agreement with experts and the EAdi signal.Keywords
This publication has 20 references indexed in Scilit:
- Efficacy of ventilator waveforms observation in detecting patient–ventilator asynchrony*Critical Care Medicine, 2011
- Neurally Adjusted Ventilatory Assist in Critically Ill Postoperative Patients: A Crossover Randomized StudyAnesthesiology, 2010
- Neurally adjusted ventilatory assist improves patient–ventilator interactionIntensive Care Medicine, 2010
- Automated detection of asynchrony in patient-ventilator interaction2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2009
- Observational study of patient-ventilator asynchrony and relationship to sedation levelJournal of Critical Care, 2009
- Patient–ventilator asynchrony during non-invasive ventilation for acute respiratory failure: a multicenter studyIntensive Care Medicine, 2009
- Detecting ineffective triggering in the expiratory phase in mechanically ventilated patients based on airway flow and pressure deflection: Feasibility of using a computer algorithm*Critical Care Medicine, 2008
- Automatic detection of ineffective triggering and double triggering during mechanical ventilationIntensive Care Medicine, 2007
- Patient-ventilator asynchrony during assisted mechanical ventilationIntensive Care Medicine, 2006
- Patient–ventilator interactionBritish Journal of Anaesthesia, 2003