Three-dimensional printing as an aid to airway evaluation after tracheotomy in a patient with laryngeal carcinoma
Open Access
- 1 December 2015
- journal article
- case report
- Published by Springer Nature in BMC Anesthesiology
- Vol. 16 (1) , 1-4
Abstract
Difficult airway may result in significant morbidity and mortality. Proficient airway evaluation, therefore, is one of the key elements in the safe conduct of anesthesia. A three-dimensional (3D) printing model was recently introduced for medical application. 3D printing is a fast, convenient, and relatively affordable technique. We present a case in which a 3D-printed airway model was successfully used for airway evaluation. A 77-year-old man who had previously undergone total laryngectomy was scheduled for resection of a pelvic mass. The condition of his airway, however, complicated the procedure. Routine methods to evaluate his airway were not suitable. Therefore, the patient’s computed tomography imaging data were used to generate stereolithography files and then to print out 3D models of his trachea. These 3D models enhanced our understanding of his tracheal morphology. They helped us devise a preanesthesia plan and effectively execute it without complications. 3D printing models allow better understanding of morphological changes in the airway and aid preanesthesia planning. The successful outcome of our case suggests 3D printing is a potent tool for evaluating difficult and more widespread use is encouraged.Keywords
Funding Information
- Supported by a college-level key development program of clinical research for Peking University Third Hospital
This publication has 13 references indexed in Scilit:
- 3D-Printed ABS and PLA Scaffolds for Cartilage and Nucleus Pulposus Tissue RegenerationInternational Journal of Molecular Sciences, 2015
- Is There a Gold Standard for Management of the Difficult Airway?Anesthesiology Clinics, 2015
- Primary and salvage total laryngectomy. Influential factors, complications, and survival.2015
- What is missing for difficult airway management in the 21st centuryBrazilian Journal of Anesthesiology (English Edition), 2015
- O que falta para o manejo de via aérea difícil no século 21Revista Brasileira de Anestesiologia, 2015
- Novel Application of Rapid Prototyping for Simulation of Bronchoscopic AnatomyJournal of Cardiothoracic and Vascular Anesthesia, 2014
- 3D‐Printed haptic “Reverse” models for preoperative planning in soft tissue reconstruction: A case reportMicrosurgery, 2014
- Tracheal stenosis after intubation and/or tracheostomyThe Egyptian Journal of Chest Diseases and Tuberculosis, 2014
- Bioresorbable Airway Splint Created with a Three-Dimensional PrinterThe New England journal of medicine, 2013
- Evaluación de un protocolo de predicción de vía aérea difícil en la práctica habitual: estudio de concordanciaRevista Española de Anestesiología y Reanimación, 2010