Abstract
Background: Brain magnetic resonance imaging (MRI) at 5 T offers unprecedented spatial resolution but is often limited by long scan times. Acceleration techniques, such as compressed sensing (CS) and artificial intelligence‐assisted compressed sensing (ACS), have the potential to speed up the acquisition process while maintaining image quality. This study aims to evaluate and compare the performance of CS and ACS (with various acceleration factors) in brain MRI imaging at 5 T.Methods: In this study, we enrolled 12 healthy volunteers and compared ACS‐accelerated 5 T brain MRI with conventional methods of CS. The ACS acceleration factors for the brain protocol, consisting of 3D T1‐weighted sequences and 2D T2‐weighted sequences, were optimized in a pilot study on healthy volunteers (acceleration factor, 2.06–3.41× in T2‐weighted imaging and 3.52–8.49× in T1‐weighted imaging). We evaluated the images acquired from patients using various acceleration methods on the basis of acquisition times, the signal‐to‐noise ratio (SNR), the contrast‐to‐noise ratio, subjective image quality, and diagnostic agreement.Results: Our findings revealed that ACS acceleration significantly reduced the acquisition times for T1‐ and T2‐weighted sequences by up to 43% and 53%, respectively, compared with traditional CS at 5 T. Importantly, this acceleration was achieved while maintaining excellent image quality, demonstrated by higher or comparable SNR and contrast‐to‐noise ratio values.Conclusions: The optimal ACS acceleration factors for 5 T brain MRI were determined to be 2.73× for 2D T2‐weighted sequences and 6.5× for 3D T1‐weighted sequences. ACS not only facilitates rapid imaging but also ensures comparable image quality and diagnostic performance, highlighting its potential to revolutionize high‐field MRI scanning.Keywords
This publication has 22 references indexed in Scilit:
- Deep learning‐based reconstruction of interventional tools and devices from four X‐ray projections for tomographic interventional guidanceMedical Physics, 2021
- Diagnostic quality assessment of compressed SENSE accelerated magnetic resonance images in standard neuroimaging protocol: Choosing the right accelerationPhysica Medica, 2021
- Deep learning reconstruction for cardiac magnetic resonance fingerprinting T1 and T2 mappingMagnetic Resonance in Medicine, 2020
- Artificial Intelligence for MR Image Reconstruction: An Overview for CliniciansJournal of Magnetic Resonance Imaging, 2020
- High-resolution MRI using compressed sensing-sensitivity encoding (CS-SENSE) for patients with suspected neurovascular compression syndrome: comparison with the conventional SENSE parallel acquisition techniqueClinical Radiology, 2019
- Accelerated MRI of the Lumbar Spine Using Compressed Sensing: Quality and EfficiencyJournal of Magnetic Resonance Imaging, 2018
- Accelerating knee MR imaging: Compressed sensing in isotropic three-dimensional fast spin-echo sequenceMagnetic Resonance Imaging, 2018
- Signal‐to‐noise ratio and MR tissue parameters in human brain imaging at 3, 7, and 9.4 tesla using current receive coil arraysMagnetic Resonance in Medicine, 2015
- Whole‐body imaging at 7T: Preliminary resultsMagnetic Resonance in Medicine, 2008
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007