Microwave Imaging Using Noise Signals
- 10 September 2018
- journal article
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 66 (12) , 5842-5851
Abstract
A new method of active incoherent microwave imaging is presented that uses noise signals and spatial frequency sampling. Building on interferometric spatial frequency sampling arrays developed in radio astronomy, active incoherent microwave imaging utilizes the transmission of noise signals to implement the first active imaging method that samples in the spatial frequency domain. In comparison to passive microwave imaging systems, active incoherent imaging requires receivers with far less sensitivity, and thus less overall cost. We present the theory behind the imaging technique and show experimental results from a 5.85-GHz system imaging in one and two dimensions. For 1-D images, the transmitter consisted of two noise generators, while the receive array was a synthesized linear array with elements placed in 1λ increments with the widest spacing of 15λ. For 2-D images, the transmitter consisted of three noise generators, while the receive array was a synthesized T-array with elements placed in 0.5λ increments. We demonstrate the reconstruction of 1-D and 2-D scenes consisting of spherical reflecting targets, using only 25 MHz of signal bandwidth and 10 μs of integration time, both of which are an order of magnitude less than passive microwave and millimeter-wave imaging systems.Keywords
Funding Information
- National Science Foundation (1708820)
This publication has 31 references indexed in Scilit:
- DDS-Based Signal-Generation Architecture Comparison for an Imaging Radar at 300 GHzIEEE Transactions on Instrumentation and Measurement, 2015
- Stable and Robust Sampling Strategies for Compressive ImagingIEEE Transactions on Image Processing, 2013
- MIMO-SAR: Opportunities and PitfallsIEEE Transactions on Geoscience and Remote Sensing, 2013
- Metamaterial Apertures for Computational ImagingScience, 2013
- A 350-GHz high-resolution high-sensitivity passive video imaging system2010
- Through-wall radar imaging using UWB noise waveformsJournal of the Franklin Institute, 2008
- Microwave imaging via space-time beamforming for early detection of breast cancerIEEE Transactions on Antennas and Propagation, 2003
- Three-dimensional millimeter-wave imaging for concealed weapon detectionIEEE Transactions on Microwave Theory and Techniques, 2001
- Doppler estimation using a coherent ultrawide-band random noise radarIEEE Transactions on Antennas and Propagation, 2000
- Infrared focal plane array technologyProceedings of the IEEE, 1991