CHARACTERIZATION OF A COMMERCIALLY-AVAILABLE, OPTICALLY-STIMULATED LUMINESCENT DOSIMETRY SYSTEM FOR USE IN COMPUTED TOMOGRAPHY
Authors:
- Lindsey LavoieLLLindsey Lavoie
- Monica GhitaMGMonica Ghita
- Libby BratemanLBLibby Brateman
- Manuel ArreolaMAManuel Arreola
- 1 September 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Health Physics
- Vol. 101 (3) , 299-310
Abstract
Optically-stimulated luminescent (OSL) nanoDot dosimeters, commercially available from Landauer, Inc. (Glenwood, IL), were assessed for use in computed tomography (CT) for erasure and reusability, linearity and reproducibility of response, and angular and energy response in different scattering conditions. Following overnight exposure to fluorescent room light, the residual signal on the dosimeters was 2%. The response of the dosimeters to identical exposures was consistent, and reported doses were within 4% of each other. The dosimeters responded linearly with dose up to 1 Gy. The dosimeter response to the CT beams decreased with increased tube voltage, showing up to a -16% difference when compared to a 0.6-cm(3) NIST-traceable calibrated ionization chamber for a 135 kVp CT beam. The largest range in percent difference in dosimeter response to scatter at central and peripheral positions inside CTDI phantoms was 14% at 80 kVp CT tube voltage, when compared to the ionization chamber. The dosimeters responded uniformly to x-ray tube angle over the ranges of increments of 0° to 75° and 105° to 180° when exposed in air, and from 0° to 360° when exposed inside a CTDI phantom. While energy and scatter correction factors should be applied to dosimeter readings for the purpose of determining absolute doses, these corrections are straightforward but depend on the accuracy of the ionization chamber used for cross-calibration. The linearity and angular responses, combined with the ability to reuse the dosimeters, make this OSL system an excellent choice for clinical CT dose measurements.Keywords
This publication has 8 references indexed in Scilit:
- Radiotherapy dosimetry using a commercial OSL systemMedical Physics, 2008
- Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurementsMedical Physics, 2007
- Optically stimulated luminescence (OSL) of carbon‐doped aluminum oxide for film dosimetry in radiotherapyMedical Physics, 2007
- The trouble withMedical Physics, 2007
- High-precision dosimetry for radiotherapy using the optically stimulated luminescence technique and thin Al2O3:C dosimetersPhysics in Medicine & Biology, 2005
- Enlarged longitudinal dose profiles in cone‐beam CT and the need for modified dosimetryMedical Physics, 2005
- A new look at CT dose measurement: Beyond CTDIMedical Physics, 2003
- Characterisation of Al2O3 for Use in Thermally and Optically Stimulated Luminescence DosimetryRadiation Protection Dosimetry, 1999