Inferior results at long‐term follow‐up after extensor mechanism allograft reconstruction in septic compared to aseptic revision total knee arthroplasty
Authors:
- 3 January 2023
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (4) , 1477-1482
Abstract
Purpose: Extensor mechanism lesion after total knee arthroplasty (TKA) is a catastrophic complication. Reconstruction with extensor mechanism allograft (EMA) has been described as a sound salvage procedure. Its effectiveness at long term and in septic cases is still under scrutiny. The long‐term results of EMA reconstruction for chronic extensor mechanism failures following aseptic and septic revision TKA have been analysed.Methods: From the institutional database, 35 patients with a revision TKA (RevTKA) undergoing EMA reconstruction from 2005 to 2015 have been retrospectively identified. A history of periprosthetic joint infection (PJI) was found in 13 (37%) patients. The mean follow‐up was 81.2 months (± 34.7, range 3–120). EMA failures were considered for lag more than 20°, Knee Society Score (KSS) less than 60 points, and/or in the case of revision of the allograft.Results: The mean KSS improved from 35.9 (± 16.9, range 0–54) to 86.6 (± 10.4, range 54–99) points in the aseptic group (p < 0.001) and from 27.5 (± 11.6, range 10–44) to 79.4 (± 16.3, range 48–94) points in the septic group (p < 0.001). The extensor lag changed from 48.4° (± 14.5, range 30–90) to 4.6° (± 10.8, range 0–50) in the aseptic group (p < 0.001) and from 56.5° (± 20.8, range 30–90) to 6.1° (± 6.8, range 0–20) in the septic group (p < 0.001). The mean postoperative flexion was 105.2° (± 13.2, range 75–130) in the aseptic group and 102.7° (± 12.5, range 80–120) in the septic group (p = 0.32). Three failures (14% of the cases) occurred in the aseptic group and five in the septic group (38% of the cases). The overall survivorship at 10 years was 83.3% (22 cases, CI95 94.2–121.7) vs 58% (13 cases, CI95 67.2–111.7) in the aseptic and septic group, respectively (p = 0.01).Conclusions: EMA reconstruction after extensor mechanism disruptions in TKA is a reliable salvage procedure. The septic nature of the revision decreased the functionality of the knee joint after EMA, but it did not represent a risk factor for re‐ruptures or recurrence of infection.Level of evidence: Level III.Keywords
This publication has 13 references indexed in Scilit:
- Extensor Mechanism Reconstruction with Use of Marlex MeshJournal of Bone and Joint Surgery, 2018
- Survivorship of Extensor Mechanism Allograft Reconstruction After Total Knee ArthroplastyThe Journal of Arthroplasty, 2017
- Surgical options for chronic patellar tendon rupture in total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2016
- Extensor Mechanism Allograft Reconstruction for Extensor Mechanism Failure Following Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2015
- Complications involving the extensor mechanism after total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2014
- Reconstruction of Patellar Tendon Disruption After Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2011
- Extended Medial Gastrocnemius Rotational Flap for Treatment of Chronic Knee Extensor Mechanism Deficiency in Patients with and without Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2004
- Characterizing the Functional Improvement After Total Shoulder Arthroplasty for OsteoarthritisJournal of Bone and Joint Surgery, 2002
- Patellar tendon avulsion after total knee arthroplastyThe Journal of Arthroplasty, 1995
- Extensor mechanism complications following total knee arthroplastyThe Journal of Arthroplasty, 1987