Prospective Trial of Sacroiliac Joint Fusion Using 3D-Printed Triangular Titanium Implants
Open Access
- 1 June 2020
- journal article
- research article
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. ume 13, 173-182
Abstract
Background: Prior trials provide strong evidence supporting minimally invasive sacroiliac joint (SIJ) fusion using triangular titanium implants (TTI) for chronic SIJ dysfunction. Objective: To assess the safety and effectiveness of SIJF using a 3D-printed TTI. Methods: Fifty-one subjects with carefully diagnosed SIJ dysfunction underwent SIJF with 3D TTI. Subjects completed pain, disability and quality of life questionnaires at baseline and 3, 6 and 12 months postoperatively. Functional tests were performed in the clinic at each visit. Pelvic CT scans were independently evaluated for radiolucency, bridging bone and other endpoints. Results: Ninety percent had 12-month follow-up. Dysfunction due to pain (Oswestry Disability Index [ODI]) decreased from 52.8 at baseline to 27.9 at 12 months (p< .0001 for change, p=.004 for non-inferiority primary hypothesis). SIJ pain scores improved from 78 preoperatively to 21 at 12-month follow-up (P< .0001). Ninety-six percent experienced an improvement of 20 points or more in VAS SIJ pain by month 12. The percentage of subjects reporting minimal difficulty performing physical activities typically impaired by back/SIJ pain improved significantly for all activities. The proportion of subjects taking opioids for SIJ pain decreased from 57% to 22%. Three physical function tests improved markedly from baseline to 1 year. Positive radiographic findings were observed, including a 70% and 77% rate of bone bridging observed at 6 and 12 months, respectively. There was no evidence of device breakage, migration or subsidence. Conclusion: In this prospective multicenter trial, SIJF with 3D-printed TTI markedly improved pain, disability and quality of life. Results are consistent with 3 prior prospective multicenter trials of a milled implant but suggest accelerated bony fusion with the newer implant. Physical function improved, and high rates of opioid cessation were observed. Level of Evidence: Level II.Keywords
This publication has 30 references indexed in Scilit:
- Open versus minimally invasive sacroiliac joint fusion: a multi-center comparison of perioperative measures and clinical outcomesAnnals of Surgical Innovation and Research, 2013
- Minimally invasive sacroiliac joint fusion: one-year outcomes in 18 patientsAnnals of Surgical Innovation and Research, 2013
- Minimally Invasive Sacroiliac Joint Fusion: One-Year Outcomes in 40 PatientsAdvances in Orthopedics, 2013
- MIS Fusion of the SI Joint: Does Prior Lumbar Spinal Fusion Affect Patient Outcomes?The Open Orthopaedics Journal, 2013
- Intraoperative laser angiography using the SPY system: review of the literature and recommendations for useAnnals of Surgical Innovation and Research, 2013
- One year successful outcomes for novel sacroiliac joint arthrodesis systemAnnals of Surgical Innovation and Research, 2012
- Sacroiliac Joint Arthrodesis-MIS Technique with Titanium Implants: Report of the First 50 Patients and OutcomesThe Open Orthopaedics Journal, 2012
- Results of Sacroiliac Joint Double Block and Value of Sacroiliac Pain Provocation Tests in 54 Patients With Low Back PainSpine, 1996
- EuroQol - a new facility for the measurement of health-related quality of lifeHealth Policy, 1990
- Human agency in social cognitive theory.American Psychologist, 1989