Effects of metal fluoride/sulfide microparticles generated by consecutive high-pulse-power breakdowns on the insulating performance in compressed SF 6
Authors:
- Wenlong YanWYWenlong Yan
- Zhenxing WangZWZhenxing Wang
- Wei ShangWSWei Shang
- Jiancang SuJSJiancang Su
- Zhiyuan CaoZCZhiyuan Cao
- Zhipeng ZhouZZZhipeng Zhou
- Liqiong SunLSLiqiong Sun
- Jianhua WangJWJianhua Wang
- 8 October 2020
- journal article
- research article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (50) , 505203
Abstract
Spark gas switches (SGS) are widely used in various pulsed power applications where sulfur hexafluoride (SF 6 ) is still dominant because of its excellent insulating performance. However, particle contamination generated by SF 6 possesses some special properties that can greatly reduce the effectiveness of the gas switches. The objective of this paper is to study the effects of particles generated spontaneously by consecutive breakdowns of high-pulse-power SGS on the insulating performance in compressed SF 6 . A double electrode/double pulse method, coupled with laser scattering and laser shadow photography, is adopted to detect the particles and examine their specific roles in the breakdown process. Many large particles in SF 6 , of approximately 150 μm in diameter, are observed at about 80 milliseconds after a single breakdown. Furthermore, numerous particles gradually suspend and accumulate in the gap after consecutive breakdowns. Particles generated by SF 6 can reach tens of micrometers in size. They have rough microtopography covered by abundant floccules, and contain rich electronegative elements: fluorine and sulfur. Moreover, particle-involved abnormal breakdowns in SF 6 usually occur with nearly equal threshold and probability in spite of the increasing consecutive breakdowns, and conversely, the abnormal breakdowns in N 2 appear more frequently and unsteadily with a high dispersibility. The analysis of field enhancement caused by these large metal-fluoride/sulfide particles shows that they can directly cause significant field emission (FE) due to their properties of surface-field enhancement and causticity. Such FE further triggers micro-discharge. Subsequently, this behavior eventually leads to abnormal breakdowns at a lower threshold.Keywords
Funding Information
- National Natural Science Foundation of China (No. 51807147)
- Natural Science Basic Research Plan in Shaanxi Province of China (No.2019JM-158)
This publication has 64 references indexed in Scilit:
- Dynamics of microparticles in vacuum breakdown: Cranberg’s scenario updated by numerical modelingPhysical Review Accelerators and Beams, 2017
- Review of Inductive Pulsed Power Generators for RailgunsIEEE Transactions on Plasma Science, 2017
- Motion analysis of spherical metal particle in AC gas-insulated lines: random effects and resistance of the SF6/N2 mixtureIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- Space-time evolution of ejected plasma for the triggering of gas switchPhysics of Plasmas, 2016
- Electrode Erosion Characteristics of Repetitive Long-Life Gas Spark Switch Under Airtight ConditionsIEEE Transactions on Plasma Science, 2015
- Influence of tiny metal particles on charge accumulation phenomena of GIS model spacer in high-pressure SF6 gasIEEE Transactions on Dielectrics and Electrical Insulation, 2013
- A picosecond-jitter electron-beam-triggered high-voltage gas spark gapIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- Limitation on Prepulse Level for Cone-Guided Fast-Ignition Inertial Confinement FusionPhysical Review Letters, 2010
- The influence of the dielectric strength of the N/sub 2//SF/sub 6/-insulation by conducting particle on the spacer surfaceIEEE Transactions on Dielectrics and Electrical Insulation, 2003
- Free Conducting Particles in a Coaxial Compressed-Gas-Insulated SystemIEEE Transactions on Power Apparatus and Systems, 1970