Abstract
To balance the power difference between the pulsed output power and constant input power, the cascaded pulsed load power supply (PLPS) has been proposed in pulsed load applications. In the cascaded PLPS, since the back-end converter is designed with high bandwidth to track pulsed load current, the pulsed power would be easily propagated into the front-end converter. Hence, the pulsed power leads to a large input current ripple and affects the operation of the sensitive power source. In this paper, the performance of the control scheme to suppress input current ripple is investigated from the perspective of the impedance model, and the requirements of the expected impedance are given. To further reduce the input current ripple and improve the dynamic response, impedance-shaping control (ISC) is proposed to reshape the inductor branch impedance. The design considerations for the proposed control schemes are studied. Finally, the cascaded PLPS comprising a phase-shift full-bridge (PSFB) converter and an interleaved buck converter are fabricated to verify the validity of the proposed control schemes.
Funding Information
  • Fundamental Research Funds for the Central Universities (2682024GF001)
  • National Natural Science Foundation of China (52277201)
  • Sichuan Provincial Engineering Research Center of High Efficiency Power Converter Technology

This publication has 18 references indexed in Scilit: