Liquid sampling–atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry: preliminary parametric evaluation and figures of merit
- 12 September 2011
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 402 (1) , 261-268
Abstract
A new, low-power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling–atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (−1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications, other than removing the electrospray ionization source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra, including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements indicate that sodium concentrations of up to 50 μg mL−1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. While solution-based concentration LOD levels of 0.02–2 μg mL−1 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to single-nanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of −1, and gas flow rates −1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively coupled plasma sources typically employed in elemental mass spectrometry.Keywords
This publication has 39 references indexed in Scilit:
- Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source for Elemental Mass SpectrometryAnalytical Chemistry, 2011
- Determination of Elemental Constituents in Different Matrix Materials and Flow Injection Studies by the Electrolyte Cathode Glow Discharge Technique with a New DesignAnalytical Chemistry, 2009
- Spectrochemical Analysis by Using Discharge Devices with Solution ElectrodesAnalytical Chemistry, 2009
- Compact Glow Discharge for the Elemental Analysis of Aqueous SamplesAnalytical Chemistry, 2007
- High-Throughput Elemental Analysis of Small Aqueous Samples by Emission Spectrometry with a Compact, Atmospheric-Pressure Solution-Cathode Glow DischargeAnalytical Chemistry, 2007
- Use of electrolyte cathode glow discharge (ELCAD) for the analysis of complex mixturesJournal of Analytical Atomic Spectrometry, 2007
- Detection of Aqueous Metals Using a Microglow Discharge Atomic Emission SensorSensor Letters, 2004
- Development of an Atmospheric Pressure Glow Discharge Detector for Capillary Column Gas ChromatographyMicrochimica Acta, 2000
- Ion spray interface for combined liquid chromatography/atmospheric pressure ionization mass spectrometryAnalytical Chemistry, 1987
- Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elementsAnalytical Chemistry, 1980