An ambulatory urodynamic examination was performed on 28 non-neurogenic incontinent patients in whom classical cystometry could not confirm objectively the history and clinical diagnosis of urinary incontinence. In 12 of 13 stress-incontinent patients, real leakage could be demonstrated. Of 15 patients with mixed incontinence, bladder instability was found in 8 and urethral instability in 2. Voiding detrusor pressures in ambulatory measurements were ∼10 cm H2O higher than in classical cystometry, although the voided volumes were lower. Advantages and pitfalls of ambulatory detrusor pressure monitoring are discussed. Neurourol. Urodynam. 17:129–133, 1998.