Reproducibility assessment of a biomechanical model-based elasticity imaging method for identifying changes in left ventricular mechanical stiffness
- 1 September 2022
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 9 (05) , 056001-16
Abstract
PurposeCardiotoxicity of antineoplastic therapies is increasingly a risk to cancer patients treated with curative intent with years of life to protect. Studies highlight the importance of identifying early cardiac decline in cancer patients undergoing cardiotoxic therapies. Accurate tools to study this are a critical clinical need. Current and emerging methods for assessing cardiotoxicity are too coarse for identifying preclinical cardiac degradation or too cumbersome for clinical implementation.ApproachIn the previous work, we developed a noninvasive biomechanical model-based elasticity imaging methodology (BEIM) to assess mechanical stiffness changes of the left ventricle (LV) based on routine cine cardiac magnetic resonance (CMR) images. We examine this methodology to assess methodological reproducibility. We assessed a cohort of 10 participants that underwent test/retest short-axis CMR imaging at baseline and follow-up sessions as part of a previous publicly available study. We compare test images to retest images acquired within the same session to assess within-session reproducibility. We also compare test and retest images acquired at the baseline imaging session to test and retest images acquired at the follow-up imaging session to assess between-session reproducibility.ResultsWe establish the within-session and between-session reproducibility of our method, with global elasticity demonstrating repeatability within a range previously demonstrated in cardiac strain imaging studies. We demonstrate increased repeatability of global elasticity compared to segmental elasticity for both within-session and between-session. Within-subject coefficients of variation for within-session test/retest images globally for all modulus directions and a mechanical fractional mechanical stiffness anisotropy metric ranged from 11% to 28%.ConclusionsResults suggest that our methodology can reproducibly generate estimates of relative mechanical elasticity of the LV and provides a threshold for distinguishing true changes in myocardial mechanical stiffness from experimental variation. BEIM has applications in identifying preclinical cardiotoxicity in breast cancer patients undergoing antineoplastic therapies.Keywords
This publication has 30 references indexed in Scilit:
- Cardiotoxicity of systemic agents used in breast cancerThe Breast, 2014
- ITK: enabling reproducible research and open scienceFrontiers in Neuroinformatics, 2014
- A Validation of Two-Dimensional In Vivo Regional Strain Computed from Displacement Encoding with Stimulated Echoes (DENSE), in Reference to Tagged Magnetic Resonance Imaging and Studies in RepeatabilityAnnals of Biomedical Engineering, 2013
- Diffuse myocardial fibrosis by T1-mapping in children with subclinical anthracycline cardiotoxicity: relationship to exercise capacity, cumulative dose and remodelingJournal of Cardiovascular Magnetic Resonance, 2013
- Model-based elastography: a survey of approaches to the inverse elasticity problemPhysics in Medicine & Biology, 2012
- Design and validation of Segment - freely available software for cardiovascular image analysisBMC Medical Imaging, 2010
- Chemotherapy and Cardiotoxicity in Older Breast Cancer Patients: A Population-Based StudyJournal of Clinical Oncology, 2005
- The late consequences of anthracycline treatment on left ventricular function after treatment for childhood cancerEuropean Journal of Pediatrics, 2003
- Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the HeartCirculation, 2002
- Hypertrophic cardiomyopathy: the interrelation of disarray, fibrosis, and small vessel diseaseHeart, 2000