Design and Development of Effective Transmission Mechanisms on a Tendon Driven Hand Orthosis for Stroke Patients
Authors:
- 1 May 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2281-2287
Abstract
Tendon-driven hand orthoses have advantages over exoskeletons with respect to wearability and safety because of their low-profile design and ability to fit a range of patients without requiring custom joint alignment. However, no existing study on a wearable tendon-driven hand orthosis for stroke patients presents evidence that such devices can overcome spasticity given repeated use and fatigue, or discusses transmission efficiency. In this study, we propose two designs that provide effective force transmission by increasing moment arms around finger joints. We evaluate the designs with geometric models and experiment using a 3D-printed artificial finger to find force and joint angle characteristics of the suggested structures. We also perform clinical tests with stroke patients to demonstrate the feasibility of the designs. The testing supports the hypothesis that the proposed designs efficiently elicit extension of the digits in patients with spasticity as compared to existing baselines.Keywords
All Related Versions
This publication has 23 references indexed in Scilit:
- A soft exoskeleton for hand assistive and rehabilitation application using pneumatic actuators with variable stiffness2015
- Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing SystemIEEE Robotics & Automation Magazine, 2015
- A Powered Finger–Thumb Wearable Hand Exoskeleton With Self-Aligning Joint AxesIEEE/ASME Transactions on Mechatronics, 2014
- Feasibility of SaeboFlex Upper-limb Training in Acute Stroke Rehabilitation: A Clinical Case SeriesOccupational Therapy International, 2014
- Development of a Biomimetic Hand Exotendon Device (BiomHED) for Restoration of Functional Hand Movement Post-StrokeIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2014
- A new hand exoskeleton device for rehabilitation using a three-layered sliding spring mechanism2013
- Use of a Novel Robotic Interface to Study Finger Motor ControlAnnals of Biomedical Engineering, 2009
- Weakness Is the Primary Contributor to Finger Impairment in Chronic StrokeArchives of Physical Medicine and Rehabilitation, 2006
- Motor rehabilitation and brain plasticity after hemiparetic strokeProgress in Neurobiology, 2004
- Chronic Motor Dysfunction After StrokeStroke, 2000