Separation and characterization of clindamycin phosphate and related impurities in injection by liquid chromatography/electrospray ionization mass spectrometry
Authors:
- 16 February 2009
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (6) , 899-906
Abstract
A simple high‐performance liquid chromatography/electrospray ionization tandem mass spectrometric (HPLC/ESI‐MS/MS) method has been developed for the rapid identification of clindamycin phosphate and its degradation products or related impurities in clindamycin phosphate injection. Detection was performed by quadrupole time‐of‐flight mass spectrometry (Q‐TOFMS) via an ESI source in positive mode. Clindamycin phosphate and its related substances lincomycin, 7‐epilincomycin‐2‐phosphate, lincomycin‐2‐phosphate, clindamycin B, clindamycin B‐2‐phosphate, and clindamycin were identified simultaneously by HPLC/ESI‐MS/MS results. Based on the MS/MS spectra of their quasi‐molecular ions, the fragmentation pathways of clindamycin phosphate and its related substances were compared and proposed, which are specific and useful for the identification of the lincosamide antibiotics and related impurities. The method was rapid, sensitive and specific and can be used to identify clindamycin phosphate and its related impurities in clindamycin phosphate injection without control compounds. Copyright © 2009 John Wiley & Sons, Ltd.Keywords
This publication has 11 references indexed in Scilit:
- Mass spectrometry analysis of in vitro nitration of a recombinant human IgG1 monoclonal antibodyRapid Communications in Mass Spectrometry, 2007
- Separation and characterization of clindamycin and related impurities in bulk drug by high-performance liquid chromatography-electrospray tandem mass spectrometryJournal of Pharmaceutical and Biomedical Analysis, 2006
- Simultaneous determination of tretinoin and clindamycin phosphate and their degradation products in topical formulations by reverse phase HPLCJournal of Separation Science, 2004
- Determination of clindamycin in animal plasma by high‐performance liquid chromatography combined with electrospray ionization mass spectrometryJournal of Mass Spectrometry, 2002
- Moist-Heat Sterilization and the Chemical Stability of Heat-Labile Parenteral SolutionsDrug Development and Industrial Pharmacy, 1998
- High-performance liquid chromatography of clindamycin and clindamycin phosphate with electrochemical detectionJournal of Chromatography A, 1990
- A high-performance liquid chromatographic assay for clindamycin phosphate and its principal degradation product in bulk drug and formulationsJournal of Pharmaceutical and Biomedical Analysis, 1985
- High-Pressure Liquid Chromatographic Assays for Clindamycin, Clindamycin Phosphate, and Clindamycin PalmitateJournal of Pharmaceutical Sciences, 1978
- Hydrolysis of Lincomycin-2-phosphate and Clindamycin-2-PhosphateJournal of Pharmaceutical Sciences, 1970
- Aqueous Stability of ClindamycinJournal of Pharmaceutical Sciences, 1970