Performance of the ablation index during pulmonary vein isolation: periprocedural data from a multicenter registry
Authors:
- Nigar Z. GasimovaNGNigar Z. Gasimova
- Anatoly A. NechepurenkoANAnatoly A. Nechepurenko
- Evgeny B. KropotkinEKEvgeny B. Kropotkin
- Eduard A. IvanitskyEIEduard A. Ivanitsky
- Grigorii V. KoluninGKGrigorii V. Kolunin
- Bor AntolicBABor Antolic
- Elena A. ArtyukhinaEAElena A. Artyukhina
- Ayan S. AbdrakhmanovAAAyan S. Abdrakhmanov
- Konstantin S. KorolevKKKonstantin S. Korolev
- Dmitry S. LebedevDLDmitry S. Lebedev
- Evgeny N. MikhaylovEMEvgeny N. Mikhaylov
- 16 May 2022
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 65 (1) , 167-177
Abstract
Purpose Our study aimed to assess the achievement of target ablation index (AI) values and their impact on first-pass pulmonary vein isolation (FPI) as well as to identify FPI predictors. Methods Atrial fibrillation (AF) ablation was performed according to the local practice, and target AIs were evaluated. The actual AI was calculated as the median value of all ablation points for the anterior and posterior left atrial (LA) walls. Results A total of 450 patients from nine centers were enrolled. Patients with first-time ablation (n = 408) were divided into the FPI and non-FPI groups. In the FPI group, a higher median target AI was reported for both the anterior and posterior LA walls than those in the non-FPI group. A higher actual AI was observed for the anterior LA wall in the FPI group. The actual AI was equal to or higher than the target AI for the posterior, anterior, and both LA walls in 54%, 47%, and 35% (n = 158) cases, respectively. Parameters such as hypertension, stroke, ablation power, actual AI value on the anterior wall, target AI values on both LA walls, AI achievement on the posterior wall, carina ablation, and operator experience were all associated with FPI in a univariate logistic regression model; only carina ablation was an independent predictor of FPI. Conclusions According to our multicenter study, FPI and a target AI were not achieved in a significant proportion of AF ablation procedures. Higher actual and target AI values were associated with FPI, but only carina ablation can independently predict FPI.Keywords
This publication has 28 references indexed in Scilit:
- 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillationEP Europace, 2017
- Relationship Between Pulmonary Vein Reconnection and Atrial Fibrillation RecurrenceJACC: Clinical Electrophysiology, 2016
- Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target valuesEP Europace, 2016
- Who is the operator, that is the question: a multicentre study of catheter ablation of atrial fibrillationEP Europace, 2016
- Low incidence of permanent complications during catheter ablation for atrial fibrillation using open-irrigated catheters: a multicentre registryEP Europace, 2014
- Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2010
- Localization of Atrial Fibrillation Triggers in Patients Undergoing Pulmonary Vein IsolationJACC, 2008
- The Important Role of Pulmonary Vein Carina Ablation as an Adjunct to Circumferential Pulmonary Vein IsolationJournal of Cardiovascular Electrophysiology, 2008
- Electrophysiological End Point for Catheter Ablation of Atrial Fibrillation Initiated From Multiple Pulmonary Venous FociCirculation, 2000
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsNew England Journal of Medicine, 1998