Results of Intertrochanteric Femur Fractures Treated With a 135-Degree Sliding Screw With a Two-Hole Side Plate
Authors:
- Paul R. RussoPRPaul R. Russo
- Barbara CarmenBCBarbara Carmen
- 1 January 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 13 (1) , 5-8
Abstract
To observe and report the clinical results of the treatment of intertrochanteric hip fractures treated with a 135-degree hip screw with a two-hole side plate. Prospective consecutive. Community private practice. A consecutive series of seventy primarily older patients with intertrochanteric hip fractures treated in a community hospital setting. Surgical treatment with a 135-degree sliding hip screw and a two-hole side plate. Healing rate and time, operative blood loss and time, incidence of hardware failure, and complications including loss of side plate fixation and amount of collapse. Sixty-nine patients, with seventy intertrochanteric hip fractures, underwent surgical treatment with a 135-degree sliding hip screw and a two-hole side plate. There were twenty-one (30 percent) A1.1, sixteen (23 percent) A1.2, twenty-one (30 percent) A2.1, and twelve (17 percent) A2.2 fractures in twenty-three (33 percent) men and forty-six (67 percent) women. Average age was seventy-nine years. The average estimated blood loss was seventy-seven cubic centimeters (range 10 to 300 cubic centimeters), and the average surgical time was thirty-one minutes (range 8 to 90 minutes). The average time to union was fifteen weeks (range 8 to 17 weeks). There were three failures: two from screw cut-out and one from screw plate dissociation. No cases failed due to loss of fixation of the two-hole side plate. Collapse was minimum in fifty-five patients (79 percent), moderate in twelve patients (17 percent), and severe in two patients (3 percent). Use of the 135-degree sliding hip screw with a two-hole side plate produces satisfactory healing and results in relatively low blood loss and short surgical times without the loss of side plate fixation.Keywords
This publication has 24 references indexed in Scilit:
- How to minimize failures of fixation of unstable intertrochanteric fracturesInjury, 1995
- Implant failures in patients with proximal fractures of the femur treated with a sliding screw deviceInjury, 1989
- Clinical Evaluation of the Sliding Compression Screw in 121 Hip FracturesSouthern Medical Journal, 1980
- Unstable Trochanteric Fractures:A Comparative Analysis of Four Methods of Internal FixationActa Orthopaedica, 1980
- Mechanical Strength of Sliding Screw-Plate hip Implants:A Biomechanical Study of Unstable Trochanteric Fractures. VIActa Orthopaedica, 1980
- A Clinical and Biomechanical StudyClinical Orthopaedics and Related Research, 1980
- TREATMENT OF INTERTROCHANTERIC HIP FRACTURES WITH A COMPRESSION HIP SCREW AND A NAIL PLATE1976
- The Richards Compression and Sliding Hip Screw System in the Treatment of Intertrochanteric FracturesActa Orthopaedica, 1974
- SLIDING SCREW PLATE FIXATION OF INTERTROCHANTERIC FEMORAL FRACTURES1972
- TROCHANTERIC FRACTURES TREATED BY THE SLIDING SCREW PLATE FIXATION METHOD1964