Displaced dual‐mode imaging with desorption electrospray ionization for simultaneous mass spectrometry imaging in both polarities and with several scan modes
- 11 March 2013
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 48 (3) , 361-366
Abstract
Displaced dual‐mode imaging (DDI) is introduced as a method for simultaneous imaging in positive and negative‐ion mode on the same sample with desorption electrospray ionization imaging, as well as a method for simultaneous imaging in full‐scan and tandem mass spectrometry (MS/MS) mode. DDI is performed by using a smaller row distance in the y‐direction than the desired image resolution and recording for example every second row in positive‐ion mode and the other half of the rows in negative‐ion mode, thus resulting in two separate images. This causes some degree of oversampling, which is thus utilized to obtain complementary mass spectrometric of the sample. Imaging with both polarities is exemplified on an imprint of a Hypericum perforatum leaf containing secondary metabolites which ionize in both polarites and a mouse kidney containing phospholipids which ionize in positive or negative mode only. Simultaneous full‐scan and MS/MS imaging was demonstrated on the same mouse kidney, as the mouse had been given a relatively low dose of the antidepressive drug amitriptyline. While the full‐scan data allowed imaging of the endogenous phospholipids, the drug and its metabolites were only visible in the MS/MS images. The latter approach is useful, for example in whole‐body imaging experiments where the full‐scan data gives an overview of the tissue, and the MS/MS mode provides the sensitivity to image trace amounts of drugs and metabolites. Copyright © 2013 John Wiley & Sons, Ltd.Keywords
This publication has 21 references indexed in Scilit:
- Ambient Mass Spectrometry Imaging: A Comparison of Desorption Ionization by Sonic Spray and ElectrosprayJournal of the American Society for Mass Spectrometry, 2012
- imzML — A common data format for the flexible exchange and processing of mass spectrometry imaging dataJournal of Proteomics, 2012
- Sublimation of New Matrix Candidates for High Spatial Resolution Imaging Mass Spectrometry of Lipids: Enhanced Information in Both Positive and Negative Polarities after 1,5-Diaminonapthalene DepositionAnalytical Chemistry, 2012
- Characterization of barley leaf tissue using direct and indirect desorption electrospray ionization imaging mass spectrometryJournal of Mass Spectrometry, 2011
- Desorption Electrospray Ionization then MALDI Mass Spectrometry Imaging of Lipid and Protein Distributions in Single Tissue SectionsAnalytical Chemistry, 2011
- Nondestructive, Histologically Compatible Tissue Imaging by Desorption Electrospray Ionization Mass SpectrometryChemBioChem, 2011
- Analysis of Secondary Plant Metabolites by Indirect Desorption Electrospray Ionization Imaging Mass SpectrometryAnalytical Chemistry, 2011
- A concise review of mass spectrometry imagingJournal of Chromatography A, 2010
- Tissue Imaging at Atmospheric Pressure Using Desorption Electrospray Ionization (DESI) Mass SpectrometryAngewandte Chemie International Edition, 2006
- Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray IonizationScience, 2004