Cricoid Pressure Impedes Insertion of, and Ventilation Through, the ProSeal Laryngeal Mask Airway in Anesthetized, Paralyzed Patients
Authors:
- Fu S. XueFXFu S. Xue
- Ya C. XuYXYa C. Xu
- Yi LiuYLYi Liu
- Peng MaoPMPeng Mao
- Kun P. LiuKLKun P. Liu
- Quan Y. YangQYQuan Y. Yang
- Guo H. ZhangGZGuo H. Zhang
- Hai T. SunHSHai T. Sun
- 1 May 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 104 (5) , 1195-1198
Abstract
We designed this prospective self-controlled study to assess whether cricoid pressure hampers placement of and ventilation through the ProSeal laryngeal mask airway (ProSeal LMA) in anesthetized, paralyzed adult patients. After induction of anesthesia, the ProSeal LMA was inserted using the introducer tool with cricoid pressure advanced as far as possible, and the cuff pressure was set at 60 cm H2O. Ventilation adequacy and anatomic position were scored using measures previously described for ProSeal LMA assessment. Airway seal pressure was recorded. Cricoid pressure was then released, the ProSeal LMA further advanced and reseated, and the assessment repeated. Lung ventilation scores, anatomic position scores, and airway seal pressure were significantly better after release of cricoid pressure and reseating of the ProSeal LMA than in the first position, where the ProSeal LMA was seated with cricoid pressure (P < 0.05). Expiratory tidal volume during intermittent positive pressure ventilation was similar with and without cricoid pressure, but peak inspiratory pressure decreased from 28 cm H2O with cricoid pressure to 14 cm H2O without cricoid pressure (P < 0.05). Cricoid pressure applied before insertion hampered proper placement of the ProSeal LMA. Temporary cricoid pressure release during insertion allowed the device to be advanced to the proper position. After correct placement of the ProSeal LMA, application of cricoid pressure did not change tidal volume, but produced a significant increase in peak inspiratory pressure.Keywords
This publication has 27 references indexed in Scilit:
- Airway rescue in acute upper airway obstruction using a ProSeal ™ Laryngeal mask airway and an Aintree Catheter ™ : a review of the ProSeal ™ Laryngeal mask airway in the management of the difficult airwayAnaesthesia, 2005
- Prevention of aspiration under general anesthesia by use of the size 2½ ProSealTM laryngeal mask airway in a 6‐year‐old boy: a case reportPediatric Anesthesia, 2005
- Failed Obstetric Tracheal Intubation and Postoperative Respiratory Support with the ProSeal??? Laryngeal Mask AirwayAnesthesia & Analgesia, 2004
- Practice Guidelines for Management of the Difficult AirwayAnesthesiology, 2003
- Bubble Solution Diagnoses ProSeal™ Insertion into the GlottisAnesthesia & Analgesia, 2002
- A Multicenter Study Comparing the ProSeal TMand Classic TMLaryngeal Mask Airway in Anesthetized, Nonparalyzed PatientsAnesthesiology, 2002
- Positive Pressure Ventilation with the ProSeal Versus Classic Laryngeal Mask Airway: A Randomized, Crossover Study of Healthy Female PatientsAnesthesia & Analgesia, 2001
- The ProSeal Laryngeal Mask AirwayAnesthesiology, 2000
- Cricoid pressure impedes positioning and ventilation through the laryngeal mask airwayCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1996
- CRICOID PRESSURE TO CONTROL REGURGITATION OF STOMACH CONTENTS DURING INDUCTION OF ANÆSTHESIAThe Lancet, 1961