Comparison of Wound Sealability Between Femtosecond Laser–Constructed and Manual Clear Corneal Incisions in Patients Undergoing Cataract Surgery: A Pilot Study
Authors:
- Harvey Siy UyHUHarvey Siy Uy
- Sunil ShahSSSunil Shah
- Mark PackerMPMark Packer
- 1 November 2017
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 33 (11) , 744-748
Abstract
PURPOSE: To compare the sealability of femtosecond laser–constructed and manual clear corneal incisions (CCIs) in patients undergoing cataract surgery. METHODS: This prospective, randomized study included 62 eyes of 62 patients with cataract grade 1 to 2 (LOCS scale). The patients were randomly assigned (1:1) for creation of either manual CCI (with a 2.4-mm keratome) or femtosecond laser–assisted CCI (LENSAR, Inc., Orlando, FL) (31 eyes in each group) before undergoing femtosecond laser–assisted cataract surgery. Wound sealability was assessed as grade 1, 2, or 3 (1: need to reform anterior chamber and hydrate wound at end of surgery; 2: need to reform anterior chamber only; 3: formed anterior chamber, no hydration or anterior chamber reformation necessary). RESULTS: The nuclear sclerosis grade, cumulative dissipated energy and phacoemulsification time were comparable between the two groups. No complications were experienced in any of the patients. The mean wound sealability for the femtosecond laser group (2.35 ± 0.84) was statistically significantly better in comparison to the manual group (1.32 ± 0.65) ( P < .001). At the end of the surgery, 22.6% (n = 7) of eyes in the femtosecond laser group needed reformation of the anterior chamber and hydration of the wound compared to 77.4% (n = 24) of eyes in the manual group. Conversely, 58.1% (n = 18) of eyes in the femtosecond laser group compared to 9.7% (n = 3) of eyes in the manual group were observed to have a formed anterior chamber. CONCLUSIONS: Femtosecond laser–created CCIs had significantly better wound sealability compared to those created with a metal keratome. [ J Refract Surg . 2017;33(11):744–748.]Keywords
This publication has 27 references indexed in Scilit:
- Evaluation of Femtosecond Laser Clear Corneal Incision: An Experimental StudyJournal of Refractive Surgery, 2013
- OCT-Documented Incision Features and Natural History of Clear Corneal Incisions Used for Bimanual Microincision Cataract SurgeryCornea, 2011
- Femtosecond Laser–Assisted Cataract Surgery with Integrated Optical Coherence TomographyScience Translational Medicine, 2010
- Standardized Seidel test to evaluate different sutureless cataract incision configurationsJournal of Cataract & Refractive Surgery, 2010
- Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract SurgeryJournal of Refractive Surgery, 2009
- Anterior chamber instability caused by incisional leakage in coaxial phacoemulsificationJournal of Cataract & Refractive Surgery, 2009
- Analysis of clear corneal incision integrity in an ex vivo modelJournal of Cataract & Refractive Surgery, 2008
- Clear corneal incision architecture in the immediate postoperative period evaluated using optical coherence tomographyJournal of Cataract & Refractive Surgery, 2007
- In vivo architectural analysis of 3.2 mm clear corneal incisions for phacoemulsification using optical coherence tomographyJournal of Cataract & Refractive Surgery, 2006
- ASCRS White PaperJournal of Cataract & Refractive Surgery, 2006