Abstract
Background and objectives Blood components must be stored under controlled temperature conditions, for reasons of component quality and safety. However, there are occasions when components may be exposed to conditions outwith the defined limits. This study aimed to generate prospective data on the effect of red cell exposure to extremes of temperature. Materials and methods Study 1: red cell concentrates (RCC) in saline, adenine, glucose and mannitol (SAGM), made after ambient overnight hold of whole blood, were exposed to either +22°C or −2°C for up to three periods of 3 h on days 3, 8 and 15 of storage, followed by a 5 h exposure on day 29. Study 2: RCC in SAGM were exposed to 25°C for 24 or 48 h from day 2. In vitro markers of cell quality were measured during storage to 43 days, and compared with control units that had been stored at 2–6°C. Results Multiple short-term exposures to +22°C or −2°C did not cause any significant changes to pH, haemolysis, supernatant potassium, cellular ATP, 2,3-DPG, or deformability, when compared to control units. Exposure of RCC to 25°C for 24 or 48 h caused a significant fall in pH, ATP, and deformability. Conclusion Red cells may be damaged by prolonged exposure to warm temperatures, but repeated short-term exposure to 22°C or −2°C does not appear to affect the in vitro quality of RCC. It is important to note that no bacterial growth studies were performed during this study.Keywords
This publication has 15 references indexed in Scilit:
- Core temperature changes in red blood cellsTransfusion, 2011
- The effect of storing whole blood at 22°C for up to 24 hours with and without rapid cooling on the quality of red cell concentrates and fresh‐frozen plasmaTransfusion, 2008
- Altered processing of thawed red cells to improve the in vitro quality during postthaw storage at 4°CTransfusion, 2007
- Temperature-Sensitive Labels for Containers of RBCsAmerican Journal of Clinical Pathology, 2006
- A simple spectrophotometric method for the quantification of residual haemoglobin in platelet concentratesVox Sanguinis, 2004
- The viability of autologous human red cells stored in additive solution 5 and exposed to 25°C for 24 hoursTransfusion, 1999
- Effect of 24‐hour storage at 25°C on the in vitro storage characteristics of CPDA‐ 1 packed red cellsTransfusion, 1998
- In vivo regeneration of red cell 2, 3‐diphosphoglycerate following transfusion of DPG‐depleted AS‐1, AS‐3 and CPDA‐1 red cellsBritish Journal of Haematology, 1989
- Temperature Changes in Donor Blood under Different Storage ConditionsTransfusion, 1971
- Studies on Stored Whole BloodTransfusion, 1970