Modification of Aortic Cannula With an Inlet Chamber to Induce Spiral Flow and Improve Outlet Flow
- 27 December 2017
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 42 (5) , 493-499
Abstract
Physiologically, blood ejected from the left ventricle in systole exhibited spiral flow characteristics. This spiral flow has been proven to have several advantages such as lateral reduction of directed forces and thrombus formation, while it also appears to be clinically beneficial in suppressing neurological complications. In order to deliver spiral flow characteristics during cardiopulmonary bypass operation, several modifications have been made on an aortic cannula either at the internal or at the outflow tip; these modifications have proven to yield better hemodynamic performances compared to standard cannula. However, there is no modification done at the inlet part of the aortic cannula for inducing spiral flow so far. This study was carried out by attaching a spiral inducer at the inlet of an aortic cannula. Then, the hemodynamic performances of the new cannula were compared with the standard straight tip end‐hole cannula. This is achieved by modeling the cannula and attaching the cannula at a patient‐specific aorta model. Numerical approach was utilized to evaluate the hemodynamic performance, and a water jet impact experiment was used to demonstrate the jet force generated by the cannula. The new spiral flow aortic cannula has shown some improvements by reducing approximately 21% of impinging velocity near to the aortic wall, and more than 58% reduction on total force generated as compared to standard cannula.Keywords
Funding Information
- Ministry of Higher Education, Malaysia (R.J1300000.7809.4F588)
This publication has 31 references indexed in Scilit:
- Image-Guided Interventions: Technology Review and Clinical ApplicationsAnnual Review of Biomedical Engineering, 2010
- Optimal Perfusion During Cardiopulmonary Bypass: An Evidence-Based ApproachAnesthesia & Analgesia, 2009
- Hemodynamic Performance Study on Small Diameter Helical GraftsASAIO Journal, 2009
- Effect of Cannula Shape on Aortic Wall and Flow Turbulence: Hydrodynamic Study During Extracorporeal Circulation in Mock Thoracic AortaArtificial Organs, 2007
- Comparison of Newtonian and non-Newtonian flows in a two-dimensional carotid artery model using the lattice Boltzmann methodPhysics in Medicine & Biology, 2007
- Non-Newtonian blood flow in human right coronary arteries: Transient simulationsJournal of Biomechanics, 2006
- Non-Newtonian blood flow in human right coronary arteries: steady state simulationsJournal of Biomechanics, 2004
- Neurologic injury in cardiac surgical patients with a history of strokeThe Annals of Thoracic Surgery, 1996
- Aortic cannula velocimetryPerfusion, 1995
- Aortic cannulationThorax, 1969