Abstract
The current ITI Dental Implant System (Institut Straumann AG Waldenburg, Switzerland) was developed in 1985–1986 on the scientific basis and clinical experience of more than 10 years with earlier ITI implants (F-type Hollow Cylinder,1 TPS, or Swiss screw2). The initial development of these implants was the result of a collaboration between the University of Berne, Switzerland, with Dr. André Schroeder and the Institut Straumann, Waldenburg, Switzerland. Today, the system consists of three different basic shapes: the full-body screw, the hollow screw, and the hollow-cylinder implant (Figure 15.1).3,4 All implants are titanium plasma sprayed (TPS) in their bone-anchoring section, which comes in various lengths. The transmucosal portion is smoothly machined. Although it has been used in Europe and Japan since the mid-1980s, the ITI Dental Implant System was only introduced to the North American market in 1990 (Straumann USA, Cambridge, MA). The descriptions found in the following represent the system with implants and components as they are available in the United States at the time of preparation of this chapter.Keywords
This publication has 13 references indexed in Scilit:
- Peri‐implant mucosal aspects of ITI implants supporting overdentures. A five‐year longitudinal study.Clinical Oral Implants Research, 1994
- Light and Transmission Electron Microscopy of the Intact Interfaces Between Non-submerged Titanium-coated Epoxy Resin Implants and Bone or GingivaJournal of Dental Research, 1992
- Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigsJournal of Biomedical Materials Research, 1991
- Histological and histomorphometrical evaluation of tissue reactions adjacent to endosteal implants in monkey'sClinical Oral Implants Research, 1991
- Clinical evaluation of the ITI (F-type) hollow cylinder implantOral Surgery, Oral Medicine, Oral Pathology, 1990
- Tissue integration of non‐submerged implants. l‐year results of a prospective study with 100 ITI hollow‐cylinder and hollow‐screw implants.Clinical Oral Implants Research, 1990
- Titanium-coated hollow screw and reconstruction plate system for bridging of lower jaw defects: Biomechanical aspectsInternational Journal of Oral and Maxillofacial Surgery, 1988
- Titanium Plasma-sprayed (TPS) Screw Implants for the reconstruction of the edentulous mandibleJournal of Oral and Maxillofacial Surgery, 1986
- The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfacesJournal of Maxillofacial Surgery, 1981
- Preliminary evaluation of porous metal surfaced titanium for orthopedic implantsJournal of Biomedical Materials Research, 1970