The effect of pelvic movement on the accuracy of hip centre location acquired using an imageless navigation system
- 11 January 2011
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 35 (11) , 1605-1610
Abstract
Objective The aim of this study was to assess the accuracy of an imageless navigation system in localising the hip centre and to evaluate the effect of pelvic movement on the accuracy of hip centre acquisition. Material and methods A phantom leg was constructed to simulate the hip joint and upper femur. A 3D measurement device was used to measure precisely the co-ordinates of hip centre. A limber link simulated hip motion as used when defining the hip centre during computer-assisted surgery. The data generated by the 3D measurement device and the image-free navigation system was compared with increasing amounts of simulated pelvic movement. Results For moderate pelvic movement (5 mm) the mean error of the hip centre ranged between 1.5 mm and 3.9 mm with a corresponding angular error of between 0.25° and 0.64°. In conditions of excessive pelvic movement (15 mm) the mean error was 11.7 mm corresponding to an angular error of 1.9°. Conclusion This in vitro study showed accurate acquisition of the centre of hip with a surgical navigation system. These data suggest that during TKA using this computer assisted navigation system, the accuracy of insertion will not be significantly affected by moderate pelvic movement during data acquisition.Keywords
This publication has 22 references indexed in Scilit:
- Relationship between cutting errors and learning curve in computer-assisted total knee replacementInternational Orthopaedics, 2009
- Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up?International Orthopaedics, 2008
- Computer assisted versus conventional cemented total knee prostheses alignment accuracy and micromotion of the tibial componentInternational Orthopaedics, 2008
- Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplastyInternational Orthopaedics, 2008
- Genauigkeit der Bestimmung des Hüftgelenkszentrums bei der KniegelenksnavigationZeitschrift für Orthopädie und ihre Grenzgebiete, 2006
- Navigation in total knee arthroplasty. A multicenter studyInternational Orthopaedics, 2006
- Accuracy of a computer-assisted navigation system for total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2006
- Pelvic tracker effects on hip center accuracy using imageless navigationComputer Aided Surgery, 2006
- Detection of the center of the hip joint in computer-assisted surgery: An evaluation study of the Surgetics algorithmComputer Aided Surgery, 2005
- Computer-assisted knee arthroplasty versus a conventional jig-based techniqueThe Journal of Bone and Joint Surgery. British volume, 2004