A randomised study of peri-prosthetic bone density after cementedversustrabecular fixation of a polyethylene acetabular component
Authors:
Open Access
- 1 August 2011
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 93-B (8) , 1033-1044
Abstract
The ideal acetabular component is characterised by reliable, long-term fixation with physiological loading of bone and a low rate of wear. Trabecular metal is a porous construct of tantalum which promotes bony ingrowth, has a modulus of elasticity similar to that of cancellous bone, and should be an excellent material for fixation.Between 2004 and 2006, 55 patients were randomised to receive either a cemented polyethylene or a monobloc trabecular metal acetabular component with a polyethylene articular surface. We measured the peri-prosthetic bone density around the acetabular components for up to two years using dual-energy x-ray absorptiometry.We found evidence that the cemented acetabular component loaded the acetabular bone centromedially whereas the trabecular metal monobloc loaded the lateral rim and behaved like a hemispherical rigid metal component with regard to loading of the acetabular bone. We suspect that this was due to the peripheral titanium rim used for the mechanism of insertion.Keywords
This publication has 36 references indexed in Scilit:
- Modes of periacetabular load transfer to cortical and cancellous bone after cemented versus uncemented total hip arthroplasty: A prospective study using computed tomography‐assisted osteodensitometryJournal of Orthopaedic Research, 2008
- Periacetabular bone changes after uncemented total hip arthroplasty evaluated by quantitative computed tomographyActa Orthopaedica, 2006
- Evaluation of periprosthetic bone using dual-energy X-ray absorptiometry: Precision of the method and effect of operation on bone mineral densityJournal of Bone and Mineral Research, 1996
- A 12-Item Short-Form Health SurveyMedical Care, 1996
- Trabecular bone density and loading history: Regulation of connective tissue biology by mechanical energyJournal of Biomechanics, 1987
- Evaluation of Bone Cement Failure Criteria With Applications to the Acetabular RegionJournal of Biomechanical Engineering, 1983
- Periacetabular Stress Distributions After Joint Replacement with Subchondral Bone RetentionActa Orthopaedica, 1983
- Stress distributions in the acetabular region—I. Before and after total joint replacementJournal of Biomechanics, 1982
- An axisymmetric model of acetabular components in total hip arthroplastyJournal of Biomechanics, 1982
- "Modes of Failure" of Cemented Stem-type Femoral ComponentsClinical Orthopaedics and Related Research, 1979