Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study
Authors:
Open Access
- 10 November 2020
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-7
Abstract
To investigate potential correlations between objective CBCT image parameters and accuracy in endodontic working length determination ex vivo. Contrast-to-noise ratio (CNR) and spatial resolution (SR) as fundamental objective image parameters were examined using specific phantoms in seven different CBCT machines. Seven experienced observers were instructed and calibrated. The order of the CBCTs was randomized for each observer and observation. To assess intra-operator reproducibility, the procedure was repeated within six weeks with a randomized order of CBCT images. Multivariate analysis (MANOVA) did not reveal any influence of the combined image quality factors CNR and SR on measurement accuracy. Inter-operator reproducibility as assessed between the two observations was poor, with a mean intra-class correlation (ICC) of 0.48 (95%-CI 0.38, 0.59) for observation No. 1. and 0.40 (95%-CI 0.30, 0.51) for observation No. 2. Intra-operator reproducibility pooled over all observers between both observations was only moderate, with a mean ICC of 0.58 (95%-CI 0.52 to 0.64). Within the limitations of the study, objective image quality measures and exposure parameters seem not to have a significant influence on accuracy in determining endodontic root canal lengths in CBCT scans. The main factor of variance is the observer.Keywords
This publication has 31 references indexed in Scilit:
- Cone beam computed tomography in Endodontics – a reviewInternational Endodontic Journal, 2014
- Accuracy of endodontic working length determination using cone beam computed tomographyInternational Endodontic Journal, 2013
- Effective dose range for dental cone beam computed tomography scannersEuropean Journal of Radiology, 2012
- Artefacts in CBCT: a reviewDentomaxillofacial Radiology, 2011
- Consensus Interpretation in Imaging Research: Is There a Better Way?Radiology, 2010
- Electronic apex locatorsInternational Endodontic Journal, 2004
- Quality and variability in diagnostic radiologyJournal of the American College of Radiology, 2004
- Meta-analysis of the sensitivity decrement in vigilance.Psychological Bulletin, 1995
- Characterization of the point spread function and modulation transfer function of scattered radiation using a digital imaging systemMedical Physics, 1986
- The position and topography of the apical canal constriction and apical foramenInternational Endodontic Journal, 1984