Objective comparison of 4 nonlongitudinal ultrasound modalities regarding efficiency and chatter
Authors:
- Brian E. ZauggBZBrian E. Zaugg
- Jeff H. PetteyJPJeff H. Pettey
- Jason D. JensenJJJason D. Jensen
- Griffin J. JardineGJGriffin J. Jardine
- Gilbert WongGWGilbert Wong
- Randall J. OlsonRORandall J. Olson
- 1 June 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (6) , 1065-1071
Abstract
To compare efficiency and chatter of Infiniti Ozil with and without Intelligent Phacoemulsification (IP) and the Signature Ellips with and without FX. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. Brunescent 2.0 mm human lens cubes were created by an instrument devised for this study. Cubes were tested (10 per test) for time of particle removal (efficiency) and for the number of times the lens particle bounced off the tip (chatter) at 300 mm Hg and 550 mm Hg, 50% and 100% power, and 50% and 100% amplitudes (amplitude for Ozil only). Of the ultrasound settings, efficiency varied from a mean of 3.3 seconds ± 1.4 (SD) to 50.4 ± 11.7 seconds and chatter from 0.0 to 52.0 ± 16.7 bounces per run. The Ozil-IP was generally more efficient than the Ozil and the Ellips FX more efficient than the Ellips. At optimized values, the Ozil-IP and Ellips-FX were similar. In general, efficiency and chatter were better at 550 mm Hg and at 50% power. The amplitude effect was complex. Efficiency closely correlated with chatter (Pearson r(2) = .31, P<.0001). Objective comparison of phacoemulsification efficiency and chatter found that optimized Ozil-IP and Ellips-FX were similar in both parameters and in general, both performed better than preceding technology. The study parameters can significantly affect efficiency and chatter, which strongly correlate with each other.Keywords
This publication has 7 references indexed in Scilit:
- The Risk of Capsular Breakage from Phacoemulsification Needle Contact With the Lens Capsule: A Laboratory StudyAmerican Journal of Ophthalmology, 2010
- Thermal Comparison of Infiniti OZil and Signature Ellips Phacoemulsification SystemsAmerican Journal of Ophthalmology, 2010
- Comparison of torsional and longitudinal modes using phacoemulsification parametersJournal of Cataract & Refractive Surgery, 2009
- Torsional mode versus conventional ultrasound mode phacoemulsificationJournal of Cataract & Refractive Surgery, 2007
- Identification of free radicals produced during phacoemulsificationJournal of Cataract & Refractive Surgery, 2001
- Use of power modulations in phacoemulsificationJournal of Cataract & Refractive Surgery, 2001
- Risk factors for corneal endothelial injury during phacoemulsificationJournal of Cataract & Refractive Surgery, 1996