Analysis of the Fire Behavior of Building-Integrated Photovoltaics (BIPV) as Façade Materials
Open Access
- 3 December 2025
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12807
Abstract
This study provides a comprehensive analysis of the fire hazards associated with Building-Integrated Photovoltaics (BIPV), using Aluminum Composite Panels (ACP) as a benchmark. Large-scale fire tests, modified from ISO 13785-1, were conducted on vertically installed BIPV modules to observe their fire behavior under conditions simulating a severe fire. The experimental process involved measuring key fire performance indicators, leading to the identification of a cascading failure mechanism. The BIPV modules demonstrated a peak Heat Release Rate (HRR) up to hi times higher (max. 898 kW) and smoke production nearly 10 times greater than the ACP baseline. The analysis reveals a distinct, multi-stage failure sequence that defines the systemic fire hazard of BIPV. Initially, a phenomenon strongly indicative of a chimney effect within the rear air cavity accelerates concealed fire spread. This rapid heating induces thermal stress, leading to extensive specimen damage termed cracking. This cracking event acts as a critical turning point, triggering a rapid release of trapped pyrolyzates and driving the fire to its peak intensity. This chain of events constitutes a unique hazard signature not observed in conventional cladding. The findings conclude that the fire risk of BIPV is a systemic issue, challenging the adequacy of component-level testing and highlighting the need for safety standards that assess the façade as a complete assembly.Keywords
This publication has 11 references indexed in Scilit:
- Experimental investigations on the influence of ‘chimney-effect’ on fire response of rainscreen façades in high-rise buildingsJournal of Building Engineering, 2021
- A state-of-the-art review of fire safety of photovoltaic systems in buildingsJournal of Cleaner Production, 2021
- Evaluating the fire risk associated with cladding panels: An overview of fire incidents, policies, and future perspective in fire standardsFire and Materials, 2021
- Experimental study of flame spread underneath photovoltaic (PV) modulesFire Safety Journal, 2021
- Impact of flat roof–integrated solar photovoltaic installation mode on building fire safetyFire and Materials, 2019
- Fire‐induced reradiation underneath photovoltaic arrays on flat roofsFire and Materials, 2018
- First developments of a new test to evaluate the fire behavior of photovoltaic modules on roofsFire Safety Journal, 2015
- Fire Hazards of Exterior Wall Assemblies Containing Combustible Components2015
- The Path to the Building Integrated Photovoltaics of TomorrowEnergy Procedia, 2012