Feasibility of cerebral near‐infrared spectroscopy monitoring in the pre‐hospital environment
Authors:
- 11 January 2012
- journal article
- emergency medicine
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 56 (2) , 172-177
Abstract
Background: Traumatic brain injury (TBI) is a significant cause of death and severe disability from trauma. Pre‐hospital care of patients with TBI may be aided by non‐invasive monitoring of cerebral tissue oxygenation. This pilot observational study was designed to assess if cerebral tissue oximetry using near‐infrared spectroscopy (NIRS) is feasible in the pre‐hospital and transport environment.Methods: After ethics committee review, we undertook a feasibility trial in healthy volunteers, transported by road ambulance or helicopter, to assess if monitoring signals could be obtained in the outside environment and during patient transport.Results: A total of 33 road ambulance transports and 32 helicopter transports were undertaken. For monitoring commenced outdoors, 33 of 66 probes applied (50%) provided adequate monitoring signal. For road transports, 33 out of 33 transports (100%) resulted in successful bilateral monitoring for more than 70% of the sampling period. For helicopter transports, four transports were cut short by battery failure during the mission and 24 of 28 transports (85.7%) resulted in successful bilateral monitoring for more than 70% of the sampling period. While patient and transport platform movement did not impact on monitoring signals, exposure to ambient light provided a challenge in obtaining monitoring signals that is nevertheless manageable with increased probe shielding.Conclusions: NIRS monitoring is feasible in the pre‐hospital environment, opening up the possibility for further research of the role of this modality in this setting.Keywords
This publication has 23 references indexed in Scilit:
- Near-Infrared Spectroscopy in the Critical SettingPediatric Emergency Care, 2011
- The principles of aeromedical retrieval of the critically illTrends in Anaesthesia and Critical Care, 2011
- Noninvasive Monitoring of Cerebrovascular Reactivity with Near Infrared Spectroscopy in Head-Injured PatientsJournal of Neurotrauma, 2010
- Continuous Assessment of Cerebral Autoregulation With Near-Infrared Spectroscopy in Adults After Subarachnoid HemorrhageStroke, 2010
- Increase in cerebral aerobic metabolism by normobaric hyperoxia after traumatic brain injuryJournal of Neurosurgery, 2008
- Near-Infrared Spectroscopy: An Important Monitoring Tool During Hybrid Aortic Arch ReplacementAnesthesia & Analgesia, 2008
- The Application of Near-infrared Oximetry to Cerebral Monitoring During Aneurysm Embolization: A Comparison With Intraprocedural AngiographyJournal of Neurosurgical Anesthesiology, 2007
- The Accuracy of Near-Infrared Spectroscopy in Detection of Subdural and Epidural Hematomas2006
- Diminished Blalock‐Taussig shunt flow detected by cerebral oximetryPediatric Anesthesia, 2006
- Interference of Cerebral Near-Infrared Oximetry in Patients with IcterusAnesthesia & Analgesia, 2000