Brain Morphometrics Correlations With Age Among 350 Participants Imaged With Both 3T and 7T MRI: 7T Improves Statistical Power and Reduces Required Sample Size
Open Access
- 14 March 2025
- journal article
- Published by Wiley in Human Brain Mapping
- Vol. 46 (4) , e70195
Abstract
Magnetic resonance imaging (MRI) at 7T has a superior signal‐to‐noise ratio to 3T but also presents higher signal inhomogeneities and geometric distortions. A key knowledge gap is to robustly investigate the sensitivity and accuracy of 3T and 7T MRI in assessing brain morphometrics. This study aims to (a) aggregate a large number of paired 3T and 7T scans to evaluate their differences in quantitative brain morphological assessment using a widely available brain segmentation tool, FreeSurfer, as well as to (b) examine the impact of normalization methods for subject variability and smaller sample sizes on data analysis. A total of 401 healthy participants aged 29–68 were imaged at both 3T and 7T. Structural T1‐weighted magnetization‐prepared rapid gradient‐echo (MPRAGE) images were processed and segmented using FreeSurfer. To account for head size variability, the brain volumes underwent intracranial volume (ICV) correction using the Residual (regression model) and Proportional (simple division to ICV) methods. The resulting volumes and thicknesses were correlated with age using Pearson's correlation and false discovery rate correction. The correlations were also calculated in increasing sample size from three to the whole sample to estimate the sample size required to detect aging‐related brain variation. Three hundred and fifty subjects (208 females) passed the image quality control, with 51 subjects excluded due to excessive motion artifacts on 3T, 7T, or both. 7T MRI showed an overall stronger correlation between morphometrics and age and a larger number of significantly correlated brain volumes and cortical thicknesses. While the ICV is consistent between both field strengths, the Residual normalization method shows markedly higher correlation with age for 3T when compared with the Proportional normalization method. The 7T results are consistent regardless of the normalization method used. In a large cohort of healthy participants with paired 3T and 7T scans, we compared the statistical performance in assessing age‐related brain morphological changes. Our study reaffirmed the inverse correlation between brain volumes and cortical thicknesses and age and highlighted varying correlations in different brain regions and normalization methods at 3T and 7T. 7T imaging significantly improves statistical power and thus reduces the required sample size.Keywords
Funding Information
- National Institutes of Health (P01AG025204, P01HL040962, R01AG053504, R01DK110041, R01MH111265, R56AG074467, RF1AG053504)
This publication has 30 references indexed in Scilit:
- Automated volumetry and regional thickness analysis of hippocampal subfields and medial temporal cortical structures in mild cognitive impairmentHuman Brain Mapping, 2014
- What is normal in normal aging? Effects of aging, amyloid and Alzheimer's disease on the cerebral cortex and the hippocampusProgress in Neurobiology, 2014
- Brain Changes in Older Adults at Very Low Risk for Alzheimer's DiseaseThe Journal of Neuroscience, 2013
- Cortical thickness determination of the human brain using high resolution 3T and 7T MRI dataNeuroImage, 2013
- FreeSurferNeuroImage, 2012
- Structural Brain Changes in Aging: Courses, Causes and Cognitive ConsequencesReviews in the Neurosciences, 2010
- The Cortical Signature of Alzheimer's Disease: Regionally Specific Cortical Thinning Relates to Symptom Severity in Very Mild to Mild AD Dementia and is Detectable in Asymptomatic Amyloid-Positive IndividualsCerebral Cortex, 2008
- Insight into RF power requirements and B1 field homogeneity for human MRI via rigorous FDTD approachJournal of Magnetic Resonance Imaging, 2007
- In‐depth study of the electromagnetics of ultrahigh‐field MRINMR in Biomedicine, 2006
- Effects of static and radiofrequency magnetic field inhomogeneity in ultra-high field magnetic resonance imagingMagnetic Resonance Imaging, 2006