Thermal and Energy Performance Assessment of the Prefab Electric Ondol System for Floor Heating in a Residential Building
Open Access
Abstract
In South Korea, radiant floor heating has been used from old housing to the recently constructed residential buildings, which is called “Ondol”. The Ondol system is generally a water-based system and it uses hot water as a heat medium provided by boilers fueled by natural gas. With great effort to reduce greenhouse gas emissions, electric Ondol panels have been increasingly applied to the recent residential buildings for floor heating. While the prefab electric Ondol panels were developed with the demand for dry construction method, the information about the prefab electric Ondol system is not sufficient. For the present study, the thermal performance of the prefab electric Ondol panels was investigated through field measurement. In addition, the heating energy and economic performance of the electric panel were compared with the conventional Ondol system. As a result, a significant surface temperature difference was observed. Moreover, the heating cost for the prefab electric Ondol system was more expensive than the conventional system, even though a heat loss was observed by the operation of the conventional system.Keywords
This publication has 24 references indexed in Scilit:
- Energy use of households in apartment complexes with different service lifeEnergy and Buildings, 2013
- A decision support assessment of cogeneration plant for a community energy system in KoreaEnergy Policy, 2012
- Estimation of CO2 emission of apartment buildings due to major construction materials in the Republic of KoreaEnergy and Buildings, 2012
- Energy consumption characteristics of high-rise apartment buildings according to building shape and mixed-use developmentEnergy and Buildings, 2012
- Effect of building regulation on energy consumption in residential buildings in KoreaRenewable and Sustainable Energy Reviews, 2012
- Research on seasonal indoor thermal environment and residents' control behavior of cooling and heating systems in KoreaBuilding and Environment, 2009
- The natural environment control system of Korean traditional architecture: Comparison with Korean contemporary architectureBuilding and Environment, 2006
- Buttock responses to contact with finishing materials over the ONDOL floor heating system in KoreaEnergy and Buildings, 2005
- Development of a radiant heating and cooling model for building energy simulation softwareBuilding and Environment, 2004
- Historical changes and recent energy saving potential of residential heating in KoreaEnergy and Buildings, 2003