Hollow fiber-combined glucose-responsive gel technology as an in vivo electronics-free insulin delivery system
Open Access
- 17 June 2020
- journal article
- research article
- Published by Springer Nature in Communications Biology
- Vol. 3 (1) , 1-13
Abstract
Accumulating evidence demonstrates that not only sustained elevation of blood glucose levels but also the glucose fluctuation represents key determinants for diabetic complications and mortality. Current closed-loop insulin therapy option is limited to the use of electronics-based systems, although it poses some technical issues with high cost. Here we demonstrate an electronics-free, synthetic boronate gel-based insulin-diffusion-control device technology that can cope with glucose fluctuations and potentially address the electronics-derived issues. The gel was combined with hemodialysis hollow fibers and scaled suitable for rats, serving as a subcutaneously implantable, insulin-diffusion-active site in a manner dependent on the subcutaneous glucose. Continuous glucose monitoring tests revealed that our device not only normalizes average glucose level of rats, but also markedly ameliorates the fluctuations over timescale of a day without inducing hypoglycemia. With inherent stability, diffusion-dependent scalability, and week-long & acute glucose-responsiveness, our technology may offer a low-cost alternative to current electronics-based approaches.Keywords
Funding Information
- MEXT | JST | Center of Innovation Program
- MEXT | Japan Science and Technology Agency
- Ministry of Education, Culture, Sports, Science and Technology
- Japan Agency for Medical Research and Development
- Secom Science and Technology Foundation
- Terumo Foundation for Life Sciences and Arts
- Mochida Memorial Foundation for Medical and Pharmaceutical Research
- Japan Diabetes Society
- Japan Foundation for Applied Enzymology
- Ube Industries, Ltd. | Ube Foundation
- Kanagawa Academy of Science and Technology
- Ichihara International Scholarship Foundation https://www.jpss.jp/en/scholarship/122/
This publication has 34 references indexed in Scilit:
- The association between symptomatic, severe hypoglycaemia and mortality in type 2 diabetes: retrospective epidemiological analysis of the ACCORD studyBMJ, 2010
- A totally synthetic glucose responsive gel operating in physiological aqueous conditionsChemical Communications, 2010
- Continuous Glucose Monitoring and Intensive Treatment of Type 1 DiabetesNew England Journal of Medicine, 2008
- Counterpoint: Are Insulin Pumps Underutilized in Type 1 Diabetes? NoDiabetes Care, 2006
- Continuous glucose monitoring and closed‐loop systemsDiabetic Medicine, 2005
- Glucose-Responsive Polymer Gel Bearing Phenylborate Derivative as a Glucose-Sensing Moiety Operating at the Physiological pHBiomacromolecules, 2004
- Swelling and Shrinking Kinetics of Totally Synthetic, Glucose-Responsive Polymer Gel Bearing Phenylborate Derivative as a Glucose-Sensing MoietyMacromolecules, 2004
- Glucose-Responsive Polymer Bearing a Novel Phenylborate Derivative as a Glucose-Sensing Moiety Operating at Physiological pH ConditionsBiomacromolecules, 2003
- Totally Synthetic Polymer Gels Responding to External Glucose Concentration: Their Preparation and Application to On−Off Regulation of Insulin ReleaseJournal of the American Chemical Society, 1998
- The M‐Value, an Index of Blood‐sugar Control in DiabeticsActa Medica Scandinavica, 1965