Cryoultramicrotomy: evidence against melting and the use of a low temperature cement for specimen orientation
Authors:
- 1 February 1982
- journal article
- Published by Wiley in Journal of Microscopy
- Vol. 125 (2) , 157-165
Abstract
A technique is presented showing the use of toluene as a low temperature cement to attach portions of frozen tissues in the desired orientation on to the cryoultramicrotome chuck. Examples of transverse sections of skeletal and vascular smooth muscle are illustrated. Electron probe analysis of these sections indicates that the distribution of elements is maintained. Evidence is presented against through section melting based on sectioning toluene at a temperature just below its melting point (178 K). Toluene was sectioned (about 100 nm thickness) successfully at three block temperatures (177, 163 and 113 K) when the knife temperature was by 1 degree or more colder than the m.p. of toluene. In all cases the toluene sections melted when the knife temperature reached 178 K. We conclude that sufficient heat is not generated and/or transferred to the toluene sections during cryosectioning under our conditions to raise the temperature of a 100 nm section by 1 K or more.Keywords
This publication has 13 references indexed in Scilit:
- Calcium release and ionic changes in the sarcoplasmic reticulum of tetanized muscle: an electron-probe study.Journal of Cell Biology, 1981
- Application of scanning electron microscopy to x-ray analysis of frozen-hydrated sections. II. Analysis of standard solutions and artificial electrolyte gradients.Journal of Cell Biology, 1981
- Application of scanning electron microscopy to x-ray analysis of frozen-hydrated sections. I. Specimen handling techniques.Journal of Cell Biology, 1981
- Microprobe study of toad urinary bladder in absence of serosal K+The Journal of Membrane Biology, 1980
- Electron probe analysis of vascular smooth muscle. Composition of mitochondria, nuclei, and cytoplasm.Journal of Cell Biology, 1979
- Composition of vacuoles and sarcoplasmic reticulum in fatigued muscle: electron probe analysis.Proceedings of the National Academy of Sciences, 1978
- Cutting work in thick section cryomicrotomyJournal of Microscopy, 1977
- Elemental distribution in striated muscle and the effects of hypertonicity: Electron probe analysis of cryo sectionsJournal of Cell Biology, 1977
- Quantitative electron probe microanalysis of biological thin sections: Methods and validityUltramicroscopy, 1976
- Evidence against through‐section thawing whilst cutting on the ultracryotomeJournal of Microscopy, 1972