The MRI‐measured arterial input function resulting from a bolus injection of Gd‐DTPA in a rat model of stroke slightly underestimates that of Gd‐[14C]DTPA and marginally overestimates the blood‐to‐brain influx rate constant determined by Patlak plots
Open Access
- 21 May 2010
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (6) , 1502-1509
Abstract
The hypothesis that the arterial input function (AIF) of gadolinium‐diethylenetriaminepentaacetic acid injected by intravenous bolus and measured by the change in the T1‐relaxation rate (ΔR1; R1 = 1/T1) of superior sagittal sinus blood (AIF‐I) approximates the AIF of 14C‐labeled gadolinium‐diethylenetriaminepentaacetic acid measured in arterial blood (reference AIF) was tested in a rat stroke model (n = 13). Contrary to the hypothesis, the initial part of the ΔR1‐time curve was underestimated, and the area under the normalized curve for AIF‐I was about 15% lower than that for the reference AIF. Hypothetical AIFs for gadolinium‐diethylenetriaminepentaacetic acid were derived from the reference AIF values and averaged to obtain a cohort‐averaged AIF. Influx rate constants (Ki) and proton distribution volumes at zero time (Vp + Vo) were estimated with Patlak plots of AIF‐I, hypothetical AIFs, and cohort‐averaged AIFs and tissue ΔR1 data. For the regions of interest, the Kis estimated with AIF‐I were slightly but not significantly higher than those obtained with hypothetical AIFs and cohort‐averaged AIF. In contrast, Vp + Vo was significantly higher when calculated with AIF‐I. Similar estimates of Ki and Vp + Vo were obtained with hypothetical AIFs and cohort‐averaged AIF. In summary, AIF‐I underestimated the reference AIF; this shortcoming had little effect on the Ki calculated by Patlak plot but produced a significant overestimation of Vp + Vo. Magn Reson Med 63:1502–1509, 2010.Keywords
This publication has 30 references indexed in Scilit:
- Model Selection in Magnetic Resonance Imaging Measurements of Vascular Permeability: Gadomer in a 9L Model of Rat Cerebral TumorJournal of Cerebral Blood Flow & Metabolism, 2006
- Estimating the arterial input function using two reference tissues in dynamic contrast‐enhanced MRI studies: Fundamental concepts and simulationsMagnetic Resonance in Medicine, 2004
- Simultaneous measurement of arterial input function and tumor pharmacokinetics in mice by dynamic contrast enhanced imaging: Effects of transcytolemmal water exchangeMagnetic Resonance in Medicine, 2004
- Patlak plots of Gd‐DTPA MRI data yield blood–brain transfer constants concordant with those of 14C‐sucrose in areas of blood–brain openingMagnetic Resonance in Medicine, 2003
- Prediction of Impending Hemorrhagic Transformation in Ischemic Stroke Using Magnetic Resonance Imaging in RatsStroke, 1998
- Measurement of the blood‐brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental conceptsMagnetic Resonance in Medicine, 1991
- Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data. GeneralizationsJournal of Cerebral Blood Flow & Metabolism, 1985
- Tissue distribution and magnetic resonance spin lattice relaxation effects of gadolinium-DTPA.Radiology, 1985
- Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake DataJournal of Cerebral Blood Flow & Metabolism, 1983
- Chelometric Titrations Using Azoarsonic Acid IndicatorAnalytical Chemistry, 1958