Electrically Evoked Auditory Steady State Responses in Cochlear Implant Users
- 22 December 2009
- journal article
- research article
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 11 (2) , 267-282
Abstract
Auditory steady state responses are neural potentials in response to repeated auditory stimuli. This study shows that electrically evoked auditory steady state responses (EASSRs) to low-rate pulse trains can be reliably recorded by electrodes placed on the scalp of a cochlear implant (CI) user and separated from the artifacts generated by the electrical stimulation. Response properties are described, and the predictive value of EASSRs for behaviorally hearing thresholds is analyzed. For six users of a Cochlear Nucleus CI, EASSRs to symmetric biphasic pulse trains with rates between 35 and 47 Hz were recorded with seven scalp electrodes. The influence of various stimulus parameters was assessed: pulse rate, stimulus intensity, monopolar or bipolar stimulation mode, and presentation of either one pulse train on one electrode or interleaved pulse trains with different pulse rates on multiple electrodes. To compensate for the electrical artifacts caused by the stimulus pulses and radio frequency transmission, different methods of artifact reduction were employed. The validity of the recorded responses was confirmed by recording on–off responses, determination of response latency across the measured pulse rates, and comparison of amplitude growth of stimulus artifact and response amplitude. For stimulation in the 40 Hz range, response latencies of 35.6 ms (SD = 5.3 ms) were obtained. Responses to multiple simultaneous stimuli on different electrodes can be evoked, and the electrophysiological thresholds determined from EASSR amplitude growth in the 40 Hz range correlate well with behaviorally determined threshold levels for pulse rates of 41 Hz.Keywords
This publication has 58 references indexed in Scilit:
- Latencies of Auditory Steady-State Responses Recorded in Early InfancyAudiology and Neurotology, 2009
- Sensitivity to Interaural Time Differences with Combined Cochlear Implant and Acoustic StimulationJournal of the Association for Research in Otolaryngology, 2008
- Electrically Evoked Auditory Steady-State Responses in a Guinea Pig Model: Latency Estimates and Effects of Stimulus ParametersAudiology and Neurotology, 2007
- Electrically Evoked Auditory Steady-State Responses in Guinea PigsAudiology and Neurotology, 2006
- Clinical Application of Dichotic Multiple-Stimulus Auditory Steady-State Responses in High-Risk Newborns and Young ChildrenAudiology and Neurotology, 2006
- A Closed-Loop Electrical Stimulation System for Cardiac Cell CulturesIEEE Transactions on Biomedical Engineering, 2005
- Stimulus artifact cancellation in the serosal recordings of gastric myoelectric activity using wavelet transformIEEE Transactions on Biomedical Engineering, 2002
- Adaptive stimulus artifact reduction in noncortical somatosensory evoked potential studiesIEEE Transactions on Biomedical Engineering, 1998
- Pulse time modulation techniques for optical communications: a reviewIEE Proceedings J Optoelectronics, 1993
- A comparison of steady-state evoked potentials to modulated tones in awake and sleeping humansThe Journal of the Acoustical Society of America, 1991