Electrochemical Testing of a New Polyimide Thin Film Electrode for Stimulation, Recording, and Monitoring of Brain Activity
Open Access
- 21 October 2022
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1798
Abstract
Subdural electrode arrays are used for monitoring cortical activity and functional brain mapping in patients with seizures. Until recently, the only commercially available arrays were silicone-based, whose thickness and lack of conformability could impact their performance. We designed, characterized, manufactured, and obtained FDA clearance for 29-day clinical use (510(k) K192764) of a new thin-film polyimide-based electrode array. This study describes the electrochemical characterization undertaken to evaluate the quality and reliability of electrical signal recordings and stimulation of these new arrays. Two testing paradigms were performed: a short-term active soak with electrical stimulation and a 29-day passive soak. Before and after each testing paradigm, the arrays were evaluated for their electrical performance using Electrochemical Impedance Spectroscopy (EIS), Cyclic Voltammetry (CV) and Voltage Transients (VT). In all tests, the impedance remained within an acceptable range across all frequencies. The different CV curves showed no significant changes in shape or area, which is indicative of stable electrode material. The electrode polarization remained within appropriate limits to avoid hydrolysis.Keywords
Funding Information
- NeuroOne Medical Technologies Corporation
This publication has 44 references indexed in Scilit:
- In vitro and in vivo evaluation of a photosensitive polyimide thin-film microelectrode array suitable for epiretinal stimulationJournal of NeuroEngineering and Rehabilitation, 2013
- Electrodes for bio-application: recording and stimulationJournal of Physics: Conference Series, 2013
- Pathologic Findings Associated With Invasive EEG Monitoring for Medically Intractable EpilepsyAmerican Journal of Clinical Pathology, 2012
- Recording Human Electrocorticographic (ECoG) Signals for Neuroscientific Research and Real-time Functional Cortical MappingJournal of Visualized Experiments, 2012
- Voltage Biasing, Cyclic Voltammetry, & Electrical Impedance Spectroscopy for Neural InterfacesJournal of Visualized Experiments, 2012
- High-frequency Oscillations and Other Electrophysiological Biomarkers of Epilepsy: Clinical StudiesBiomarkers in Medicine, 2011
- In vivoimpedance spectroscopy of deep brain stimulation electrodesJournal of Neural Engineering, 2009
- INTRACRANIAL ELECTROENCEPHALOGRAPHY WITH SUBDURAL GRID ELECTRODESNeurosurgery, 2008
- Efficacy of Dexamathasone on Cerebral Swelling and Seizures during Subdural Grid EEG Recording in ChildrenEpilepsia, 2006
- Selection of stimulus parameters for deep brain stimulationClinical Neurophysiology, 2004