Abstract
Purpose: MP2RAGE T1‐weighted imaging has been shown to be beneficial for various applications, mainly because of its good grey‐white matter contrast, its B1‐robustness and ability to derive T1 maps. Even using parallel imaging, the method requires long acquisition times, especially at high resolution. This work aims at accelerating MP2RAGE imaging using compressed sensing.Methods: A pseudo‐phyllotactic Cartesian MP2RAGE readout was implemented allowing for flexible reordering and undersampling factors. The sampling pattern was first optimized based on fully sampled data and a compressed sensing reconstruction. Changes in contrast ratios, automated brain segmentation results, and quantitative T1 values were used for benchmarking. In vivo undersampled data from eleven healthy subjects were then acquired using a 4‐fold acceleration with the optimized sampling pattern. The resulting images were compared to the standard parallel imaging MP2RAGE protocol by visual inspection and using the above quality metrics.Results: The application of incoherent undersampling and iterative compressed sensing reconstruction on MP2RAGE acquisitions allows for a 57% time reduction (corresponding to 4‐fold undersampling with maintained reference lines, TA = 3:35 minutes) compared to the reference protocol using parallel imaging (GRAPPAx3 acceleration, TA = 8:22 minutes) while obtaining images with similar image quality, morphometric (volume differences = [0.07 ± 1.2–3.8 ± 1.9]%) and T1‐mapping outcomes (T1 error = [6 ± 5.1–37 ± 12.3] ms depending on the different structures).Conclusion: A whole‐brain MP2RAGE acquisition is feasible with compressed sensing in less than 4 minutes without appreciably compromising image quality.Keywords
This publication has 33 references indexed in Scilit:
- MRI criteria for the diagnosis of multiple sclerosis: MAGNIMS consensus guidelinesThe Lancet Neurology, 2016
- Assessing atrophy measurement techniques in dementia: Results from the MIRIAD atrophy challengeNeuroImage, 2015
- Automated detection of white matter and cortical lesions in early stages of multiple sclerosisJournal of Magnetic Resonance Imaging, 2015
- Voxel-Based Morphometry2015
- The Alzheimer's Disease Neuroimaging Initiative: Progress report and future plansAlzheimer's & Dementia, 2010
- MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high fieldNeuroImage, 2010
- T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2⁎ contrast and RF coil receive B1 sensitivity with simultaneous vessel visualizationNeuroImage, 2009
- MR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to AskRadioGraphics, 2006
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)Magnetic Resonance in Medicine, 1990