Anterior Decompression and Stabilization with the Kaneda Device for Thoracolumbar Burst Fractures Associated with Neurological Deficits* **
Authors:
- Kiyoshi KanedaKKKiyoshi Kaneda
- Hiroshi TaneichiHTHiroshi Taneichi
- Kuniyoshi AbumiKAKuniyoshi Abumi
- Tomoyuki HashimotoTHTomoyuki Hashimoto
- Shigenobu SatohSSShigenobu Satoh
- Masanori FujiyaMFMasanori Fujiya
- 1 January 1997
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 79 (1) , 69-83
Abstract
One hundred and fifty consecutive patients who had a burst fracture of the thoracolumbar spine and associated neurological deficits were managed with a single-stage anterior spinal decompression, strut-grafting, and Kaneda spinal instrumentation. At a mean of eight years (range, five years to twelve years and eleven months) after the operation, radiographs showed successful fusion of the injured spinal segment in 140 patients (93 per cent). Ten patients had a pseudarthrosis, and all were managed successfully with posterior spinal instrumentation and a posterolateral arthrodesis. The percentage of the canal that was obstructed, as measured on computed tomography, improved from a preoperative mean of 47 per cent (range, 24 to 92 per cent) to a postoperative mean of 2 per cent (range, 0 to 8 per cent). Despite breakage of the Kaneda device in nine patients, removal of the implant was not necessary in any patient. None of the patients had iatrogenic neurological deficits. After the anterior decompression, the neurological function of 142 (95 per cent) of the 150 patients improved by at least one grade, as measured with a modification of the grading scale of Frankel et al. Fifty-six (72 per cent) of the seventy-eight patients who had preoperative paralysis or dysfunction of the bladder recovered completely. One hundred and twenty-five (96 per cent) of the 130 patients who were employed before the injury returned to work after the operation, and 112 (86 per cent) of them returned to their previous job without restrictions. We concluded that anterior decompression, strut-grafting, and fixation with the Kaneda device in patients who had a burst fracture of the thoracolumbar spine and associated neurological deficits yielded good radiographic and functional results.Keywords
This publication has 24 references indexed in Scilit:
- Biomechanical Evaluation of Anterior Thoracolumbar Spinal InstrumentationSpine, 1995
- Reconstruction of an iliac crest defect with a bioactive ceramic prosthesisEuropean Spine Journal, 1994
- Unstable Thoracolumbar and Lumbar Burst Fractures Treated with the AO Fixateur InterneJournal of Spinal Disorders, 1992
- Multicenter Spine Fracture StudySpine, 1992
- Bilateral Transpedicular Decompression and Harrington Rod Stabilization in the Management of Severe Thoracolumbar Burst FracturesSpine, 1992
- Experimental Evaluation of Seven Different Spinal Fracture Internal Fixation Devices Using Nonfailure Stability TestingSpine, 1991
- Anterior Decompression and Stabilization of Thoracolumbar Burst Fractures by the Use of the Slot–Zielke DeviceSpine, 1991
- Evaluation of Surgical Treatment for Burst FracturesSpine, 1990
- Reduction of the Intracanal Fragment in Experimental Burst FracturesSpine, 1988
- The Three Column Spine and Its Significance in the Classification of Acute Thoracolumbar Spinal InjuriesSpine, 1983