Multi-Objective Optimization of Energy Saving Control for Air Conditioning System in Data Center
Open Access
Abstract
A multi-objective optimization scheme is proposed to save energy for a data center air conditioning system (ACS). Since the air handling units (AHU) and chillers are the most energy consuming facilities, the proposed energy saving control scheme aims to maximize the saved energy for these two facilities. However, the rack intake air temperature tends to increase if the energy saving control scheme applied to AHU and chillers is conducted inappropriately. Both ACS energy consumption and rack intake air temperature stabilization are set as two objectives for multi-objective optimization. The non-dominated sorting genetic algorithm II (NSGA-II) is utilized to solve the multi-objective optimization problem. In order for the NSGA-II to evaluate fitness functions that are both the ACS total power consumption and AHU outlet cold air temperature deviations from a specified range, neural network models are utilized. Feedforward neural networks are utilized to learn the power consumption models for both chillers and AHUs as well as the AHU outlet cold air temperature based on the recorded data collected in the field. The effectiveness and efficiency of the proposed energy saving control scheme is verified through practical experiments conducted on a campus data center ACS.Keywords
Funding Information
- Ministry of Science and Technology (MOST 106-3113-E-027-003)
This publication has 39 references indexed in Scilit:
- A review on airflow management in data centersApplied Energy, 2019
- Comprehensive study on the effects of plenum depths on air flow and thermal managements in data centersInternational Journal of Thermal Sciences, 2017
- A review of air conditioning energy performance in data centersRenewable and Sustainable Energy Reviews, 2017
- Energy, environmental and economical saving potential of data centers with various economizers across AustraliaApplied Energy, 2016
- Performance assessment of cooling systems in data centers; Methodology and application of a new thermal metricCase Studies in Thermal Engineering, 2016
- A case study and critical assessment in calculating power usage effectiveness for a data centreEnergy Conversion and Management, 2013
- A critical analysis of Power Usage Effectiveness and its use in communicating data center energy consumptionEnergy and Buildings, 2013
- Evaluation of air management system's thermal performance for superior cooling efficiency in high-density data centersEnergy and Buildings, 2011
- Data center design and location: Consequences for electricity use and greenhouse-gas emissionsBuilding and Environment, 2011
- Airflow distribution through perforated tiles in raised-floor data centersBuilding and Environment, 2006