Flow Rate and inlet temperature considerations for direct immersion of a single server in mineral oil
Authors:
- 1 May 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10879870,p. 706-714
Abstract
Complete immersion of servers in electrically nonconductive mineral oil has recently become a promising technique for minimizing cooling energy consumption in data centers. Liquid cooling in general offers significant advantages over traditional air cooling approaches due to the higher heat capacities of fluids. However, a lack of sufficient published data and long term reliability documentation of oil immersion cooling makes most data center operators hesitant to apply these approaches to their mission critical facilities. In this study, a single server was fully submerged horizontally in mineral oil. Experiments were conducted to observe the effects of varying the volumetric flow rate and oil inlet temperature on thermal performance and power consumption of the server. Specifically, temperature measurements of the CPUs, motherboard components, and bulk fluid were recorded at steady state conditions. Comparing with results from baseline tests performed with traditional air cooling show promise for mineral oil as a viable cooling alternative for data centers. Overall, the cooling loop was able to achieve partial power usage effectiveness (pPUECooling) values as low as 1.03. This server level study provides a preview of possible facility energy savings by utilizing high temperature, low flow rate oil for cooling. A discussion on additional opportunities for optimization of IT hardware and implementation of oil cooling is also included.Keywords
This publication has 11 references indexed in Scilit:
- Combining Computational Fluid Dynamics (CFD) and Flow Network Modeling (FNM) for Design of a Multi-Chip Module (MCM) Cold Plate2013
- Aquasar: A hot water cooled data center with direct energy reuseEnergy, 2012
- Novel heat transfer fluids for direct immersion phase change cooling of electronic systemsInternational Journal of Heat and Mass Transfer, 2012
- Computational fluid dynamic investigation of liquid rack cooling in data centresApplied Energy, 2012
- Immersion cooling nucleate boiling of high power computer chipsEnergy Conversion and Management, 2012
- Energy Efficiency Analyses and Comparison of Air and Water Cooled High Performance Servers2009
- Enhancement of pool boiling critical heat flux in dielectric liquids by microporous coatingsInternational Journal of Heat and Mass Transfer, 2007
- An investigation of the thermal performance of an oil filled transformer windingIEEE Transactions on Power Delivery, 1992
- Microelectronic Cooling by Enhanced Pool Boiling of a Dielectric Fluorocarbon LiquidJournal of Heat Transfer, 1989
- Conduction Cooling for an LSI Package: A One-Dimensional ApproachIBM Journal of Research and Development, 1982