Abstract
BACKGROUND AND PURPOSE: Hemodynamics are thought to play a role in intracranial aneurysm growth and rupture. Computational fluid dynamics is frequently performed to assess intra-aneurysmal hemodynamics, using generalized flow waveforms of healthy volunteers as inflow boundary conditions. The purpose of this study was to assess differences in inflow conditions for different aneurysmal parent artery locations and variations of circle of Willis configurations. MATERIALS AND METHODS: In a series of 96 patients with 103 aneurysms, velocity measurements were acquired using 2D phase-contrast MR imaging perpendicular to the aneurysmal parent arteries in the circle of Willis. Circle of Willis configurations were inspected for variations using multiple overlapping thin-slab-acquisition MRAs. Flow rates, velocity magnitudes, and pulsatility indices were calculated for each parent artery location in subgroups of complete and incomplete circle of Willis configurations. RESULTS: Flow rates, velocity magnitudes, and pulsatility indices were significantly different among aneurysmal parent arteries. Incomplete circle of Willis configurations were observed in 24% of the cases. Significantly lower basilar artery flow rates were observed in configurations with hypoplastic P1 segments. Significantly higher A1 flow rates were observed in configurations with a hypoplastic contralateral A1 segment. CONCLUSIONS: Inflow conditions vary substantially between aneurysmal parent arteries and circle of Willis configurations. We have created a collection of parent artery–specific inflow conditions tailored to the patient-specific circle of Willis configuration that can be used in future computational fluid dynamics studies analyzing intra-aneurysmal hemodynamics.Keywords
Funding Information
- Nuts-Ohra Foundation
- Stichting Toegepast Wetenschappelijk Instituut voor Neuromodulatie (TWIN)
This publication has 28 references indexed in Scilit:
- Morphologic and Hemodynamic Risk Factors in Ruptured Aneurysms Imaged before and after RuptureAmerican Journal of Neuroradiology, 2014
- Mind the Gap: Impact of Computational Fluid Dynamics Solution Strategy on Prediction of Intracranial Aneurysm Hemodynamics and Rupture Status IndicatorsAmerican Journal of Neuroradiology, 2013
- The Natural Course of Unruptured Cerebral Aneurysms in a Japanese CohortNew England Journal of Medicine, 2012
- Prevalence of unruptured intracranial aneurysms, with emphasis on sex, age, comorbidity, country, and time period: a systematic review and meta-analysisThe Lancet Neurology, 2011
- Hemodynamic–Morphologic Discriminants for Intracranial Aneurysm RuptureStroke, 2011
- Sensitivity of patient-specific numerical simulation of cerebal aneurysm hemodynamics to inflow boundary conditionsJournal of Neurosurgery, 2007
- Cerebral AneurysmsNew England Journal of Medicine, 2006
- Blood-flow models of the circle of Willis from magnetic resonance dataJournal of Engineering Mathematics, 2003
- Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatmentThe Lancet, 2003
- Quantification of blood flow in the middle cerebral artery with phase-contrast MR imagingEuropean Radiology, 2000