Effect of heat application on the physicochemical properties of new endodontic sealers: an in vitro and SEM study
Authors:
- 9 December 2023
- journal article
- research article
- Published by Springer Nature in Odontology
- Vol. 112 (2) , 512-525
Abstract
Understanding the properties of endodontic sealers is vital for treatment planning. Calcium silicate-based sealers are important in modern endodontics. This study investigates the effect of heat on the physicochemical properties of new calcium silicate sealers, addressing concerns raised by clinicians seeking to combine their benefits with the gutta-percha obturation technique. Five endodontic sealers (AH Plus Bioceramic®, Total Fill® BC®, One-fil® Bioceramic, K-Biocer, Any-seal®) were evaluated. Each sealer (n = 16/group) was either kept at 37 °C or subjected to heat at 60 or 200 °C for 30 s. ISO 6876-2012 standards were used to measure setting time, flow, film thickness, and dimensional changes over time. SEM and EDS were utilized for surface and chemical analysis. Data analysis employed IBM SPSS Statistics version 26 with a 5% significance level for two-sided tests. The sealers' setting times were shortened by heat, except for Total Fill® BC with extended setting time. All sealers had significantly longer setting times than manufacturer specifications. Film thickness increased with temperature, while flow values decreased. K-Biocer sealer showed the highest flow (16.89 ± 0.57 mm) at 200 °C, while Total Fill® sealer had the lowest (15.32 ± 0.62 mm). Shrinkage was significant at 60 °C and 200 °C, with greater shrinkage at 200 °C. Heat caused surface deformations in all sealers. The 200 °C groups exhibited more voids in AH Plus Bioceramic®, Any-seal®, and One-fil® sealers, and higher void area in Total Fill®, One-fil®, and K-Biocer sealers (p value < 0.001). EDX analysis confirmed heat-induced chemical and elemental changes in all tested sealers. Elevated temperature affects the physicochemical properties and structure of the tested endodontic sealers. The consideration of endodontic sealer compatibility is essential when warm gutta-percha obturation techniques are used.Keywords
This publication has 28 references indexed in Scilit:
- Composition and physicochemical properties of calcium silicate based sealers: A review articleJournal of Clinical and Experimental Dentistry, 2017
- Influence of Warm Vertical Compaction Technique on Physical Properties of Root Canal SealersJournal of Endodontics, 2016
- Properties of Tricalcium Silicate SealersJournal of Endodontics, 2016
- Bioceramic-Based Root Canal Sealers: A ReviewInternational Journal of Biomaterials, 2016
- Physical properties and biocompatibility of an injectable calcium-silicate-based root canal sealer: in vitro and in vivo studyBMC Oral Health, 2015
- Sealers and Warm Gutta-percha Obturation TechniquesJournal of Endodontics, 2015
- In Situ Assessment of the Setting of Tricalcium Silicate–based Sealers Using a Dentin Pressure ModelJournal of Endodontics, 2015
- Investigation of the Effect of Sealer Use on the Heat Generated at the External Root Surface during Root Canal Obturation Using Warm Vertical Compaction Technique with System B Heat SourceJournal of Endodontics, 2014
- Investigation of chemical changes in sealers during application of the warm vertical compaction techniqueInternational Endodontic Journal, 2014
- Physical Properties of 5 Root Canal SealersJournal of Endodontics, 2013