Bacterial Contamination During Pacemaker Implantation Is Common and Does Not Always Result in Infection
- 1 January 2015
- journal article
- research article
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 79 (8) , 1712-1718
Abstract
Bacterial cultures of cardiovascular implantable electronic devices removed from patients without clinical infection are often positive, and the cultured bacteria are different from those at the time of clinical infection. This discrepancy has not been adequately explained. We hypothesized that the cause is bacterial contamination at operation and compared the results of bacterial cultures between patients with de novo pacemaker implantation and those with pacemaker replacement. We prospectively enrolled consecutive 100 patients who underwent cardiac pacemaker implantation (49 de novo implantations, 51 replacements). We took swab cultures from inside the generator pocket (1) immediately after the creation of new pocket or removal of old generator, (2) after connection of leads to new generator, and (3) after pocket lavage. Swab cultures were positive in 272 (45%) of 600 samples. The majority of the cultured bacteria were Propionibacterium species. No statistical difference was detected between de novo implantations and replacements in the positive ratio of swab cultures. The positive ratio was not correlated with the number of previous device replacements. The positive ratio of swab cultures was not different between new implantations and replacements, suggesting that a positive culture merely indicates contamination of bacteria during operation rather than colonization.Keywords
This publication has 22 references indexed in Scilit:
- Sonication of Explanted Cardiac Rhythm Management Devices for the Diagnosis of Pocket Infections and Asymptomatic Bacterial ColonizationPacing and Clinical Electrophysiology, 2011
- Bacterial Colonization and Infection of Electrophysiological Cardiac Devices Detected With Sonication and Swab CultureCirculation, 2010
- Update on Cardiovascular Implantable Electronic Device Infections and Their ManagementCirculation, 2010
- Infective Endocarditis Complicating Permanent Pacemaker and Implantable Cardioverter-Defibrillator InfectionMayo Clinic Proceedings, 2008
- Risk Factors Related to Infections of Implanted Pacemakers and Cardioverter-DefibrillatorsCirculation, 2007
- Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator InfectionsJACC, 2007
- Nonvalvular Cardiovascular Device–Related InfectionsCirculation, 2003
- Infections of intracardiac devicesInfectious Disease Clinics of North America, 2002
- Diagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac DevicesAnnals of Internal Medicine, 2000
- Pacemaker lead infection: echocardiographic features, management, and outcomeHeart, 1999