Removal of retained ventricular shunt catheters without craniotomy
Authors:
- Bahram ChehraziBCBahram Chehrazi
- Charles C. DuncanCDCharles C. Duncan
- 1 January 1982
- journal article
- research article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 56 (1) , 160-161
Abstract
A technique is described in which insulated suction is used to extract infected retained ventricular catheters in cases of shunt infection in humans. This procedure allows safe removal without craniotomy. Retained catheters are pulled through an insulated No. 11F or 13F suction tube attached to an electrocoagulation unit used for resection and coagulation of adhesions. The technique was successful in 2 cases with retained catheters.Keywords
This publication has 3 references indexed in Scilit:
- Prospective Randomized Study of Therapy in Cerebrospinal Fluid Shunt InfectionNeurosurgery, 1980
- Prospective randomized study of therapy in cerebrospinal fluid shunt infectionNeurosurgery, 1980
- Control of shunt infectionJournal of Neurosurgery, 1976