The effects of molecular weight on the exposure characteristics of poly(methylmethacrylate) developed at low temperatures
- 1 November 2008
- journal article
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 26 (6) , 2306-2310
Abstract
Poly(methylmethacrylate) (PMMA) with various molecular weights exposed using 50keV electron beam have been investigated at subzero developer temperatures. Contrast curves for Methyl Isobutyl Ketone (MIBK):Isopropyl Alcohol (IPA)=1:3 and MIBK:IPA=1:7 developers were determined. The contrast curves for different molecular weight PMMA resists converge into a single curve at lower temperatures. At low temperatures, the line edge roughness and resolution improved. However, minimum line pitch shows no significant improvement while dose latitudes for a particular line pitch increased. It is shown that at low temperatures, linewidth resolution and periodicity are invariant for the different PMMA molecular weights (50K to 2.2M) used in this work.Keywords
Funding Information
- NSF (ECS 04-03489)
This publication has 28 references indexed in Scilit:
- Effect of cold development on improvement in electron-beam nanopatterning resolution and line roughnessJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 2006
- Sub-10 nm electron beam lithography using cold development of poly(methylmethacrylate)Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 2004
- Low stress development of poly(methylmethacrylate) for high aspect ratio structuresJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 2002
- Influence of developer temperature and resist material on the structure quality in deep x-ray lithographyJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 1998
- Degradation of poly(methylmethacrylate) by deep ultraviolet, x-ray, electron beam, and proton beam irradiationsJournal of Vacuum Science & Technology B, 1988
- Three-dimensional photolithography with conformal GeSe resistJournal of Vacuum Science & Technology B, 1988
- Exposure and development models used in electron beam lithographyJournal of Vacuum Science and Technology, 1981
- High resolution electron-beam lithography on thin filmsJournal of Vacuum Science and Technology, 1979
- Parameters Affecting the Electron Beam Sensitivity of Poly(methyl methacrylate)IBM Journal of Research and Development, 1977
- Developer Characteristics of Poly‐(Methyl Methacrylate) Electron ResistJournal of the Electrochemical Society, 1975