Small Signal Dynamics of DFIG-Based Wind Turbines During Riding Through Symmetrical Faults in Weak AC Grid
Authors:
- 19 January 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 32 (2) , 720-730
Abstract
Instability issues of the grid-connected doubly fed induction generator (DFIG) based wind turbines (WTs) during low-voltage ride-through (LVRT) have got little attention yet. In this paper, the small-signal behavior of DFIG WTs attached to weak ac grid with high impedances during the period of LVRT is investigated, with special attention paid to the rotor-side converter. First, based on the studied LVRT strategy, the influence of the high-impedance grid is summarized as the interaction between phase-looked loop (PLL) and rotor current controller (RCC). As modal analysis result indicates that the underdamped poles are dominated by PLL, complex torque coefficient method, which is conventionally applied in power system to study the interaction between mechanical and electrical subsystems of synchronous generator, is generalized to analyze how the PLL-RCC interaction influence the phase motion of PLL. Then, the concerned small-signal stability of the PLL-synchronized DFIG system can be discerned by the developed complex phase coefficients. Impacts of PLL's and RCC's parameters are highlighted, as well as the system's operating conditions during LVRT. Finally, the analytical result is validated by experiments.Keywords
Funding Information
- National key research and development program (2016YFB0900104)
- National Natural Science Foundation of China (51277196)
This publication has 27 references indexed in Scilit:
- Modeling of Grid-Connected VSCs for Power System Small-Signal Stability Analysis in DC-Link Voltage Control TimescaleIEEE Transactions on Power Systems, 2017
- Small Signal Instability of PLL-Synchronized Type-4 Wind Turbines Connected to High-Impedance AC Grid During LVRTIEEE Transactions on Energy Conversion, 2016
- DC-Bus Voltage Control Stability Affected by AC-Bus Voltage Control in VSCs Connected to Weak AC GridsIEEE Journal of Emerging and Selected Topics in Power Electronics, 2015
- Modeling of Grid-Connected DFIG-Based Wind Turbines for DC-Link Voltage Stability AnalysisIEEE Transactions on Sustainable Energy, 2015
- Modeling of VSC Connected to Weak Grid for Stability Analysis of DC-Link Voltage ControlIEEE Journal of Emerging and Selected Topics in Power Electronics, 2015
- Impact of K‐factor and active current reduction during fault‐ride‐through of generating units connected via voltage‐sourced converters on power system stabilityIET Renewable Power Generation, 2015
- Enhanced model of the doubly fed induction generator‐based wind farm for small‐signal stability studies of weak power systemIET Renewable Power Generation, 2014
- Small-Signal Stability Analysis of a DFIG-Based Wind Power System Under Different Modes of OperationIEEE Transactions on Energy Conversion, 2009
- Small signal stability analysis and optimal control of a wind turbine with doubly fed induction generatorIET Generation, Transmission & Distribution, 2007
- Evaluation of Current Control Methods for Wind Turbines Using Doubly-Fed Induction MachinesIEEE Transactions on Power Electronics, 2005