Effect of pH and temperature on orthodontic NiTi wires immersed in acidic fluoride solution
- 9 February 2006
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 79B (1) , 7-15
Abstract
Orthodontic arch wires can confront diverse pH and temperature conditions in the oral cavity after replacement. The current study evaluated the effect of pH and temperature on orthodontic NiTi arch wires after immersion in an acidic fluoride solution. The acetic acid added for the adjustment of pH forms hydrofluoric acid (HF). More HF was formed in a solution of lower pH with higher temperature than that of the higher pH with lower temperature. Within the same pH value, the temperature of the solution affected the concentration of HF. Each as‐received wire exhibited quite different microhardness values. The reduction of microhardness, 1.2–5.7%, occurred after immersion. Within the same product, however, the pH and temperature had minor influence on the reduction. The volumetric weight change, concentration of the released elements, and surface morphology were influenced by pH and temperature. At pH 3.5 of 60°C solution, the greatest weight loss, release of elements, and corrosion of surface occurred from the wires. At pH 6, on the other hand, no such loss or release occurred regardless of temperature. At 5°C solution, the surface exhibited minor corrosion regardless of pH value. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006Keywords
This publication has 27 references indexed in Scilit:
- Surface characterization of retrieved NiTi orthodontic archwiresEuropean Journal of Orthodontics, 2000
- Chronic Renal Failure after Ingestion of Over-the-Counter Chromium PicolinateAnnals of Internal Medicine, 1997
- Influence of fluoride on titanium in an acidic environment measured by polarization resistance techniqueJournal of Applied Biomaterials, 1995
- X-ray diffraction of nitinol orthodontic arch wiresAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1995
- Corrosion and Biocompatibility of Shape Memory AlloysCorrosion Engineering, 1991
- Nitinol arch wire in a simulated oral environment. Changes in mechanical propertiesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1988
- Verification of Theoretical Modeling of Heat Transmission in Teeth by in vivo ExperimentsJournal of Dental Research, 1987
- Accelerated oxide growth on titanium implants during autoclaving caused by fluorine contaminationBiomaterials, 1985
- Beta titanium: A new orthodontic alloyAmerican Journal of Orthodontics, 1980
- Laboratory and clinical analyses of nitinol wireAmerican Journal of Orthodontics, 1978