Optimization of catheter/tissue contact during pulmonary vein isolation: the impact of atrial rhythm
Open Access
- 9 January 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (2) , 288-294
Abstract
During pulmonary vein isolation (PVI), even if operators are aware of the contact force (CF), its values may greatly vary and the impact of cardiac rhythm has not been thoroughly investigated yet. This study aims at assessing the actual values of CF, the applications with suboptimal CF, and the impact of cardiac rhythm on CF during PVI. Twenty patients undergoing point-by-point PVI with a CF-sensing catheter were considered. CF target was between 6 and 40 g. The mean CF per application (mCF) was evaluated and considered suboptimal if ≤5 g. The real-time graphic of CF was also evaluated and classified as pulsatile if regular variations synchronous with the atrial rate were seen; otherwise it was irregular. To achieve PVI, 1458 applications were delivered; 287 (19.68%) had suboptimal mCF. A great variability of mCF was seen according to anatomy, operators and patients. Compared to applications in atrial fibrillation (AF), those in sinus rhythm (SR) showed a higher median value of mCF (11 vs. 9 g; P = 0.0099) and a lower percentage of suboptimal mCF (17.95% vs. 25.15%; P = 0.0051). Compared to the irregular, the pulsatile pattern, almost exclusively observed in SR, was associated with higher mCF (14.69 ± 8.77 vs. 10.79 ± 7.89 g; P < 0.0001) and fewer suboptimal applications (8.02% vs. 27.73%; P < 0.0001). During PVI, several factors influence CF, which, despite optimization attempts, can be suboptimal in ∼20% of the applications. However, CF is higher in SR than in AF and this is strictly associated with a pulsatile pattern of instant CF values.Keywords
Funding Information
- Biosense Webster
This publication has 18 references indexed in Scilit:
- Impact of Contact Force Technology on Atrial Fibrillation Ablation: A Meta‐AnalysisJournal of the American Heart Association, 2015
- Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: A systematic review and meta-analysisHeart Rhythm, 2015
- Factors Affecting Catheter Contact in the Human Left Atrium and Their Impact on Ablation EfficacyJournal of Cardiovascular Electrophysiology, 2014
- Paroxysmal AF Catheter Ablation With a Contact Force Sensing CatheterJACC, 2014
- Catheter-tissue contact force for pulmonary veins isolation: a pilot multicentre study on effect on procedure and fluoroscopy timeEP Europace, 2013
- Left Atrial Diverticula in Patients Undergoing Atrial Fibrillation Ablation: Morphologic Analysis and Clinical ImpactJournal of Cardiovascular Electrophysiology, 2013
- Ablation Effect Indicated by Impedance Fall is Correlated with Contact Force Level During Ablation for Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2013
- Prospective Characterization of Catheter–Tissue Contact Force at Different Anatomic Sites During Antral Pulmonary Vein IsolationCirculation: Arrhythmia and Electrophysiology, 2012
- Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmiasHeart Rhythm, 2012
- A novel radiofrequency ablation catheter using contact force sensing: Toccata studyHeart Rhythm, 2012